| поискавой системы для электроныых деталей |
|
TMP461 датащи(PDF) 13 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMP461 датащи(HTML) 13 Page - Texas Instruments |
|
13 / 38 page ![]() applications attain better overall accuracy with additional series resistance. However, this increased accuracy is application-specific. When series resistance is added, the total value must not be greater than 1kΩ. If filtering is required, suggested component values are 100pF differential and 50Ω on each input; exact values are application-specific. Additionally, a digital filter is available for the remote temperature measurements to reduce the effect of noise further. This filter is programmable and has two levels when enabled. Level 1 performs a moving average of four consecutive samples. Level 1 filtering can be achieved by setting the digital filter control register (read address 24h, write address 24h) to 01h. Level 2 performs a moving average of eight consecutive samples. Level 2 filtering can be achieved by setting the digital filter control register (read address 24h, write address 24h) to 02h. The value stored in the remote temperature result register is the output of the digital filter, and is the value that the ALERT and THERM limits are compared to. The digital filter provides additional immunity to noise and spikes on the ALERT and THERM outputs. The filter responses to impulse and step inputs are shown in Figure 7-2 and Figure 7-3, respectively. The filter can be enabled or disabled by programming the desired levels in the digital filter register; see Table 8-1. The digital filter is disabled by default and on POR. 0 10 20 30 40 50 60 70 80 90 100 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Samples Disabled Level1 Level 2 Figure 7-2. Filter Response to Impulse Inputs 0 10 20 30 40 50 60 70 80 90 100 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Samples Disabled Level 1 Level 2 Figure 7-3. Filter Response to Step Inputs 7.3.5 Sensor Fault The TMP461-EP device can sense a fault at the D+ input resulting from an incorrect diode connection. The TMP461-EP device can also sense an open circuit. Short-circuit conditions return a value of –64°C. The detection circuitry consists of a voltage comparator that trips when the voltage at D+ exceeds (V+) – 0.3V (typical). The comparator output is continuously checked during a conversion. If a fault is detected, then OPEN (bit 2) in the status register is set to 1. When not using the remote sensor with the TMP461-EP device, D+ must be connected to D– or GND to prevent meaningless fault warnings. 7.3.6 ALERT and THERM Functions Operation of the ALERT (pin 10) and THERM (pin 7) interrupts is shown in Figure 7-4. Operation of the THERM (pin 7) and THERM2 (pin 10) interrupts is shown in Figure 7-5. The ALERT and THERM pin setting is determined by bit 5 of the configuration register. The hysteresis value is stored in the THERM hysteresis register and applies to both the THERM and THERM2 interrupts. The value of the CONAL[2:0] bits in the consecutive ALERT register (see Table 8-1) determines the number of limit violations before the ALERT pin is tripped. The default value is 000b and corresponds to one violation, 001b programs two consecutive violations, 011b programs three consecutive violations, and 111b programs four consecutive violations. The CONAL[2:0] bits provide additional filtering for the ALERT pin state. www.ti.com TMP461-EP SNIS241 – SEPTEMBER 2025 Copyright © 2025 Texas Instruments Incorporated Submit Document Feedback 13 Product Folder Links: TMP461-EP |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |