| поискавой системы для электроныых деталей |
|
SPC563M60X датащи(PDF) 95 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
SPC563M60X датащи(HTML) 95 Page - STMicroelectronics |
|
95 / 128 page ![]() DocID14642 Rev 12 95/128 SPC563M64x, SPC563M60x Electrical characteristics 127 4.14 Flash memory electrical characteristics 2. Maximum Frequency includes FM modulation. 3. APC must be equal to RWSC. Table 32. Program and erase specifications Symbol Parameter Min Value Typical Value(1) Initial Max(2) Max(3) Unit Tdwprogram P Double Word (64 bits) Program Time(4) —22 50 500 s T16kpperase P 16 KB Block Pre-program and Erase Time — 300 500 5000 ms T32kpperase P 32 KB Block Pre-program and Erase Time — 400 600 5000 ms T64kpperase P 64 KB Block Pre-program and Erase Time — 600 900 5000 ms T128kpperase P 128 KB Block Pre-program and Erase Time — 800 1300 7500 ms 1. Typical program and erase times assume nominal supply values and operation at 25 °C. All times are subject to change pending device characterization. 2. Initial factory condition: < 100 program/erase cycles, 25 °C, typical supply voltage. 3. The maximum program & erase times occur after the specified number of program/erase cycles. These maximum values are characterized but not guaranteed. 4. Actual hardware programming times. This does not include software overhead. Table 33. Flash module life Symbol Parameter Conditions Value Unit Min Typ P/E C Number of program/erase cycles per block for 16 Kbyte blocks over the operating temperature range (TJ) — 100,000 — cycles P/E C Number of program/erase cycles per block for 32 and 64 Kbyte blocks over operating temperature range (TJ) — 10,000 — cycles P/E C Number of program/erase cycles per block for 128 Kbyte blocks over the operating temperature range (TJ) — 1,000 — cycles Retention C Minimum data retention at 85 °C average ambient temperature(1) Blocks with 0 – 1,000 P/E cycles 20 — years Blocks with 10,000 P/E cycles 10 — years Blocks with 100,000 P/E cycles 5 — years 1. Ambient temperature averaged over duration of application, not to exceed recommended product operating temperature range. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |