| поискавой системы для электроныых деталей |
|
DAC80504 датащи(PDF) 24 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
DAC80504 датащи(HTML) 24 Page - Texas Instruments |
|
24 / 50 page ![]() No Power-On Reset Power-On Reset 1.20 Undefined 0.00 2.20 2.70 5.50 VDD (V) Specified Supply Voltage Range No Power-On Reset Power-On Reset 1.50 Undefined 0.00 0.70 1.70 5.50 VIO (V) Specified Supply Voltage Range 24 DAC80504, DAC70504, DAC60504 SBAS871C – AUGUST 2017 – REVISED JANUARY 2019 www.ti.com Product Folder Links: DAC80504 DAC70504 DAC60504 Submit Documentation Feedback Copyright © 2017–2019, Texas Instruments Incorporated 8.3.3 Device Reset Options 8.3.3.1 Power-on-Reset (POR) The DACx0504 includes a power-on reset function that controls the output voltage at power up. After the VDD and VIO supplies have been established a POR event is issued. The POR causes all registers to initialize to their default values and communication with the device is valid only after a 250 µs power-on-reset delay. The default value for all DACs is either zero-code or midscale-code as determined by the RSTSEL pin. Each DAC channel remains at the power-up voltage until a valid command is written to it. The POR circuit requires specific supply levels to discharge the internal capacitors and to reset the device on power up, as indicated in Figure 59 and Figure 60. In order to initiate a POR event, VDD or VIO must be below their corresponding low thresholds for at least 100 µs. If VDD and VIO remain above their specified high threshold a POR event will not occur. When the supplies drop below their high threshold but remain over the lower one (shown as the undefined region), the device may or may not reset under all specified temperature and power- supply conditions. Figure 59. Threshold Levels for VDD POR Circuit Figure 60. Threshold Levels for VIO POR Circuit 8.3.3.2 Software Reset A device software reset event is initiated by writing the reserved code 0x1010 to SOFT-RESET in the TRIGGER register. The software reset command is triggered on the CS rising edge of the instruction. A software reset initiates a POR event. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |