| поискавой системы для электроныых деталей |
|
LM5064PMH/NOPB датащи(PDF) 34 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
LM5064PMH/NOPB датащи(HTML) 34 Page - Texas Instruments |
|
34 / 64 page ![]() LM5064 SNVS718E – JUNE 2011 – REVISED FEBRUARY 2013 www.ti.com Table 5. OT_FAULT_LIMIT Register Value Meaning Default 0h – 0FFEh Over-temperature Fault threshold value 0960h (150°C) 0FFFh Over-temperature Fault detection disabled n/a OT_WARN_LIMIT (51h) The OT_WARN_LIMIT command is a standard PMBus command that allows configuring or reading the threshold for the over-temperature warning detection. Reading and writing to this register should use the coefficients shown in Table 41. Accesses to this command should use the PMBus read or write word protocol. If the measured temperature exceeds this value, an over-temperature warning is triggered and the OT WARN flags set in the respective registers and the SMBA signal asserted. A single temperature measurement is an average of 16 round-robin cycles; therefore, the minimum temperature warn detection time is 16 ms. Table 6. OT_WARN_LIMIT Register Value Meaning Default 0h – 0FFEh Over-Temperature Warn threshold value 07D0h (125°C) 0FFFh Over-Temperature Warn detection disabled n/a VIN_OV_WARN_LIMIT (57h) The VIN_OV_WARN_LIMIT command is a standard PMBus command that allows configuring or reading the threshold for the VIN over-voltage warning detection. Reading and writing to this register should use the coefficients shown in Table 41. Accesses to this command should use the PMBus read or write word protocol. If the measured value of VIN falls below the value in this register, VIN OV Warn flags are set in the respective registers and the SMBA signal is asserted. Table 7. VIN_OV_WARN_LIMIT Register Value Meaning Default 0h – 0FFEh VIN Over-Voltage Warning detection 0FFFh (disabled) threshold 0FFFh VIN Over-Voltage Warning disabled n/a VIN_UV_WARN_LIMIT (58h) The VIN_UV_WARN_LIMIT command is a standard PMBus command that allows configuring or reading the threshold for the VIN under-voltage warning detection. Reading and writing to this register should use the coefficients shown in Table 41. Accesses to this command should use the PMBus read or write word protocol. If the measured value of VIN falls below the value in this register, VIN UV Warn flags are set in the respective register, and the SMBA signal is asserted. Table 8. VIN_UV_WARN_LIMIT Register Value Meaning Default 1h – 0FFFh VIN Under-Voltage Warning detection 0000h (disabled) threshold 0000h VIN Under-Voltage Warning disabled n/a 34 Submit Documentation Feedback Copyright © 2011–2013, Texas Instruments Incorporated Product Folder Links: LM5064 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |