| поискавой системы для электроныых деталей |
|
MP44019GS датащи(PDF) 17 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP44019GS датащи(HTML) 17 Page - Monolithic Power Systems |
|
17 / 29 page ![]() MP44019 – CRM/DCM MULTI-MODE PFC CONTROLLER WITH SECOND OVP MP44019 Rev. 1.0 MonolithicPower.com 17 4/30/2021 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2021 MPS. All Rights Reserved. VCOMPI 22µs tD VCOMPI_BOFF VCOMPI_C2D Figure 6: Dead Time Extension The maximum dead time (tDEAD_MAX) is 23µs. During this time, COMP reaches its minimum voltage and linearly approaches 0V as the internal COMP (VCOMPI) reaches its threshold (VCOMP_C2D, typically 0.38V). With this control scheme, the system smoothly alternates between CrM and DCM as the load is gradually reduced. This means the switching frequency is automatically reduced for maximum efficiency. Figure 7 shows how the switching frequency changes in a line cycle. VAC = 230V fSW (Hz) 25% Load 64% Load 100% Load π θ Figure 7: Switching Frequency in a Line Cycle Figure 8 shows the relationship between the switching frequency and the load. fSW (Hz) VAC = 90V VAC = 265V 0% 20% 80% 60% 40% 100% Load Figure 8: Switching Frequency vs. Load Burst Mode Operation Figure 9 shows a burst mode control diagram. IP Soft On COMPI VOUT 0 393v IOUT 60mV OVP Soft Off 120mV 430v 400v 383v Figure 9: Burst Mode Control Depending on how the COMP voltage indicates the load information, the device enters DCM. The device only enters burst mode under certain loads to improve light-load efficiency and reduce standby power loss. As the load decreases, COMP gradually drops. When VCOMPI drops below VCOMPI_BOFF (typically 60mV), switching stops with five soft-off pulses. As VCOMPI ramps up to VCOMPI_BON (typically 120mV), switching resumes with five soft-on pulses. This soft-on/off control avoids abrupt inductor current changes, and attenuates the acoustic noise accordingly. During the burst-off period, the IC shuts down most of internal block to ensure that the supply current is below IQ (typically 180µA). Improved THD Under heavy loads, the MP44019 works in CrM. The average input current in one cycle can be estimated with Equation (4): AC AC IN ON EQ1 v ( ) v ( ) I ( ) t ( ) 2 L R (4) Where VAC is the RMS of the line voltage, calculated with Equation (5): AC AC v ( ) 2 V sin( ) (5) And REQ1 is the equivalent input resistor, which can be can be calculated with Equation (6): EQ1 ON 2L R t ( ) (6) Where tON (θ) is the on time. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |