| поискавой системы для электроныых деталей |
|
MP44019GS датащи(PDF) 16 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP44019GS датащи(HTML) 16 Page - Monolithic Power Systems |
|
16 / 29 page ![]() MP44019 – CRM/DCM MULTI-MODE PFC CONTROLLER WITH SECOND OVP MP44019 Rev. 1.0 MonolithicPower.com 16 4/30/2021 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2021 MPS. All Rights Reserved. Valley Switching To minimize the switching loss, the MP44019 always achieves valley switching through zero- current detection (ZCD) under any condition, regardless of DCM or CRM. A leading edge blanking time (tZCD_LEB, typically 0.3µs) is inserted to filter out the noise on ZCD after the gate turns off. The positive voltage on ZCD must exceed VZCD_H (typically 0.75V) then drop below VZCD_L (typically 0.25V) for the next trigger condition. Besides the ZCD trigger condition, the actual turn-on action should also wait for the end of the dead time extension (DTE) signal (see the Frequency Reduction function below for more details). When the DTE signal ends, and the conditions to trigger ZCD are fulfilled, the controller switches on the MOSFET after a delay time (tZCD_DELAY, typically 150ns) at the minimum drain-source voltage. The auxiliary winding turn ratio is determined by a sufficient positive voltage. VAUX_MIN can be estimated with Equation (2): ������������������������_������������������ = 1 2 × ( ������������������������−√2×������������������_������������������ ������ − ������������) ≥ ������ZCD_H (2) Where VF is the forward voltage of DZ (typically 0.7V). The winding ratio (N) can then be calculated with Equation (3): N ≤ ������������������������−√2×������������������_������������������ 2×������ZCD_H+������������ (3) Where VAC_MAX is the input’s maximum RMS voltage. A restart timer-out (tZCD_TO, typically 180µs) generates a signal to turn on the MOSFET after it switches off. This allows the MOSFET to turn on during start-up, since no valley signal can be detected on ZCD. Figure 4 shows the internal function block, as well as its peripheral circuit. LEB time 300ns 0.5V + - OCL PWM 0.75V + - LEB Time 250ns R S Q Consecutive Count = 3 OCP GATE RZCD RG RCS L1 R4 R S Q 0.75V 0.25V LEB Restart = 180µs RAMP SOFF Q + - + - STOP ZCD/CS VCOMPD tON_MAX = 30µs DT PWM PWM SOFF DZ OCP OCP Timer =50ms UVLO Figure 4: ZCD Functional Block Figure 5 shows the ZCD timing diagram. IL tSMIN tON GATE ZCD/CS ZCD LEB ZCD Detect. COMP Ramp LEB VDS LEB 0.75V 0.25V Figure 5: ZCD Timing Diagram Frequency Reduction Function The MP44019 reduces the switching frequency with DTE technology under light loads. The MP44019 works in CrM under heavy loads. In CrM, the PFC ’s frequency increases as the load is decreased, which means the switching loss becomes dominant. The MP44019 gradually inserts a dead time (tD) as the load becomes lighter. Figure 6 shows how the dead time is extended when the COMP voltage drops. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |