| поискавой системы для электроныых деталей |
|
STAC9752 датащи(PDF) 32 Page - Integrated Device Technology |
|
|
|||||||||||||||||||||||||||||
STAC9752 датащи(HTML) 32 Page - Integrated Device Technology |
|
32 / 95 page ![]() STAC9752/9753 TWO-CHANNEL, 20-BIT, AC’97 2.3 CODECS WITH HEADPHONE DRIVE, SPDIF OUTPUT MICROPHONE & JACK SENSING IDT™ 32 STAC9752/9753 REV 3.3 1206 TWO-CHANNEL, 20-BIT, AC’97 2.3 CODECS WITH HEADPHONE DRIVE, SPDIF OUTPUT MICROPHONE & JACK SENSING 1. Disable source of DAC samples in Controller 2. Set PR bit for DAC channel in Registers 26h, 2Ah, or 3Eh When it wants to power up the channel, all it needs to do is: 1. Clear PR bit for DAC channel in Registers 26h, 2Ah, or 3Eh 2. Enable source of DAC samples in Controller 5.2.3. Primary and Secondary CODEC Register Addressing The 2-bit CODEC ID field in the LSBs of Output Slot 0 is an addition to the original AC-Link protocol that enables an AC‘97 Digital Controller to independently access Primary and Secondary CODEC registers. For Primary CODEC access, the AC‘97 Digital Controller: 1. Sets the AC-Link Frame valid bit (Slot 0, bit 15) 2. Validates the tag bits for Slot 1 and 2 Command Address and Data (Slot 0, bits 14 and 13) 3. Sets a zero value (00) into the CODEC ID field (Slot 0, bits 1 and 0) 4. Transmits the desired Primary CODEC Command Address and Command Data in Slots 1 and 2 For Secondary CODEC access, the AC‘97 Digital Controller: 1. Sets the AC-Link Frame valid bit (Slot 0, bit 15) 2. Places a non-zero value (01, 10, or 11) into the CODEC ID field (Slot 0, bits 1 and 0) 3. Transmits the desired Secondary CODEC Command Address and Command Data in Slots 1 and 2 Secondary CODECs disregard the Command Address and Command Data (Slot 0, bits 14 and 13) tag bits. In a sense the Secondary CODEC ID field functions as an alternative Valid Command Address (for Secondary reads and writes) and Command Data (for Secondary writes) tag indicator. Secondary CODECs must monitor the Frame Valid bit, and ignore the frame (regardless of the state of the Secondary CODEC ID bits) if it is not valid. AC‘97 Digital Controllers should set the frame valid bit for a frame with a Secondary register access, even if no other bits in the output tag slot except the Secondary CODEC ID bits are set. 5.3. AC-Link Output Frame (SDATA_OUT) The AC-Link output frame data streams correspond to the multiplexed bundles of all digital output data targeting AC‘97’s DAC inputs and control registers. As mentioned earlier, each AC-Link output frame supports up to 12 20-bit outgoing data time slots. Slot 0 is a special reserved time slot contain- ing 16-bits which are used for AC-Link protocol infrastructure. Figure 15 illustrates the time slot based AC-Link protocol. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |