23 / 112 page ![]() 1998 Oct 07 23 Philips Semiconductors Product specification Pager baseband controller PCA5007 6.9 Serial interface SIO0: UART The UART interface of the PCA5007 implements a subset of the complete standard as defined in e.g. the P80CL580. 6.9.1 DIFFERENCES TO THE STANDARD 80C51 UART The following deviations from the standard exist: • If [SM1 and SM0] = 10 then Mode 1 (8-bit data transmission) is selected, with a fixed baud rate (4800/9600 bits/s) • If [SM1 and SM0] = 01 then Mode 2 (9-bit data transmission) is selected, with a fixed baud rate (4800/9600 bits/s) • Modes 0 and 3 and the variable baud rate selection using Timer 1 overflow is not available • The SM2 bit has no function • The time reference for Modes 1 and 2 is taken from the 76.8 kHz oscillator, instead of the original 6.9.2 UART MODES This serial port is full duplex which means that it can transmit and receive simultaneously. It is also receive-buffered and can commence reception of a second byte before a previously received byte has been read from the register. However, if the first byte has not been read by the time the reception of the second byte is complete, the second byte will be lost. The serial port receive and transmit registers are both accessed via the special function register S0BUF. Writing to S0BUF loads the transmit register and reading from S0BUF accesses a physically separate receive register. f OSC 12 ----------- The serial port can operate in 2 modes: Mode 1 10 bits are transmitted (through TXD) or received (through RXD): a START bit (0), 8 data bits (LSB first) and a STOP bit (1). On receive, the stop bit goes into RB8 in special function register S0CON (see Figs 9 and 10). Mode 2 11 bits are transmitted (through TXD) or received (through RXD): a START bit (0), 8 data bits (LSB first), a programmable 9th data bit and a STOP bit (1). On transmit, the 9th data bit (TB8 in S0CON) can be assigned the value of 0 or 1. Or, for example, the parity bit (P, in the PSW) could be moved into TB8. On receive, the 9th data bit goes into RB8 in S0CON, while the STOP bit is ignored (see Figs 9 and 11). In both modes the baud rate can be selected to either 4800 or 9600 depending on the SMOD bit in the PCON SFR. If SMOD = 0 the baud rate is 4800, if SMOD = 1 the baud rate is 9600 with a 76.8 kHz quartz crystal. In both modes, transmission is initiated by any instruction that uses S0BUF as a destination register. Reception is initiated by the incoming start bit if REN = 1. 6.9.3 SERIAL PORT CONTROL REGISTER (S0CON) The serial port control and status register is the special function register S0CON (see Table 16). The register contains not only the mode selection bits, but also the 9th data bit for transmit and receive (TB8 and RB8), and the serial port interrupt bits (TI and RI). Table 16 Serial Port Control Register (S0CON, SFR address 98H) 76543210 SM0 SM1 − REN TB8 RB8 TI RI |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |