| поискавой системы для электроныых деталей |
|
PCA5007 датащи(PDF) 21 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PCA5007 датащи(HTML) 21 Page - NXP Semiconductors |
|
21 / 112 page ![]() 1998 Oct 07 21 Philips Semiconductors Product specification Pager baseband controller PCA5007 6.8.2 SERIAL CONTROL REGISTER (S1CON) Table 7 Serial Control Register (S1CON, SFR address D8H) Table 8 Description of the S1CON bits 6.8.3 DATA SHIFT REGISTER (S1DAT) S1DAT contains the serial data to be transmitted or data which has just been received. Bit 7 is transmitted or received first; i.e. data shifted from left to right. Table 9 Data Shift Register (S1DAT, SFR address DAH) 6.8.4 ADDRESS REGISTER (S1ADR) The slave address register is not available since slave mode is not supported. 6.8.5 SERIAL STATUS REGISTER (S1STA) The contents of this register may be used as a vector to a service routine. This optimizes the response time of the software and consequently that of the I2C-bus. S1STA is a read-only register. The status codes for all available modes of a single master I2C-bus interface are given in Tables 12 to 14. 76543210 − ENS1 STA STO SI AA −− BIT SYMBOL FUNCTION S1CON.7 − CR2 is not available. S1CON.6 ENS1 Enable Serial I/O. When ENS1 = 0, the serial I/O is disabled. SDA and SCL outputs are in the high-impedance state; P1.6 and P1.7 function as open-drain ports. When ENS1 = 1, the serial I/O is enabled. Output port latches P1.6 and P1.7 must be set to logic 1. S1CON.5 STA START flag. If STA is set while the SIO is in master mode, SIO will generate a repeated START condition. S1CON.4 STO STOP flag. With this bit set while in master mode a STOP condition is generated. When a STOP condition is detected on the I2C-bus, the SIO hardware clears the STO flag. S1CON.3 SI SIO interrupt flag. This flag is set, and an interrupt is generated, after any of the following events occur: • A START condition is generated in master mode • A data byte has been received or transmitted in master mode (even if arbitration is lost). If this flag is set, the I2C-bus is halted (by pulling down SCL). Received data is only valid until this flag is reset. S1CON.2 AA Assert Acknowledge. When this bit is set, an acknowledge (LOW level to SDA) is returned during the acknowledge clock pulse on the SCL line when: • A data byte is received while the device is programmed to be a master receiver. When this bit is reset, no acknowledge is returned. S1CON.1 − CR1 and CR0 are not available. S1CON.0 − 76543210 D7 D6 D5 D4 D3 D2 D1 D0 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |