19 / 28 page ![]() ADIS16203 Rev. 0 | Page 19 of 28 20 –60 1 FREQUENCY (Hz) 10000 0 –20 –40 10 100 1000 AVG_CNT = 8 N = 256 AVG_CNT = 4 N = 16 AVG_CNT = 1 N = 2 CORE SENSOR RESPONSE Figure 30. INCL_OUT, INCL_180_OUT Filter Response 20 –60 1 FREQUENCY (Hz) 10000 0 –20 –40 10 100 1000 AVG_CNT = 8 N = 256 AVG_CNT = 4 N = 16 AVG_CNT = 1 N = 2 Figure 31. SUPPLY_OUT, AUX_ADC, and TEMP_OUT Filter Response, fS = 4096 SPS AVG_CNT Register Definition Address Default1 Format Access 0x39, 0x38 0x0007 Binary R/W 1 Default is valid only until the first register write cycle. The AVG_CNT register contains information that represents the number of averages to be applied to the output data. The number of averages can be calculated by powers of 2. The number of averages can be set to 1, 2, 4, 8, 16, 32, 64, 128, or 256. Table 17. AVG_CNT Bit Description Bit Description 15:4 Not used 3:0 Data bits (maximum = 1000, or a decimal value of 8) POWER-DOWN CONTROL The ADIS16203 has the ability to power down for user-defined amounts of time, using the SLP_CNT control register. The amount of time specified by the SLP_CNT control register is equal to the binary count of the 8-bit control word multiplied by 0.5 sec. Therefore, the 255 codes cover an overall shutdown period of 127.5 seconds. The SLP_CNT register is volatile and is set to 0 upon both power-up and subsequent wake-ups from the power-down period. By setting the SLP_CNT control register to a nonzero state, the ADIS16203 automatically powers down once the next sample period is completed and the data output registers are updated. Once the ADIS16203 is placed into power-down mode, it can only return to normal operation by timing out, by a reset command (using the RST hardware control line), or by cycling the power applied to the part. Once awake, the data output registers can be scanned to determine what the state of the output registers were prior to powering down. Once the data is recovered, the device can be powered down again by simply writing a nonzero value to the SLP_CNT control register and starting the process over. Once the power-down time is complete, the recovery time for the ADIS16203 is approximately 2 ms. This recovery time is implemented within the device to allow for recovery of the ADC prior to performing the next data conversion. Note that the ND data bit within the data output control registers is cleared when the ADIS16203 is powered down. Likewise, the new data hardware I/O line is placed into an inactive state prior to being powered down. The DAC is placed into a power-down mode as well, resulting in the DAC output dropping to 0 V during the power-down period. All control register settings are retained while powered down with the exception of the SLP_CNT control register. SLP_CNT Register Definition Address Default1 Format Access 0x3B, 0x3A 0x0000 Binary R/W 1 Default is valid only until the first register write cycle. Table 18. SLP_CNT Bit Descriptions Bit Description 15:8 Not used 7:0 Data bits |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |