| поискавой системы для электроныых деталей |
|
ADIS16203/PCBZ датащи(PDF) 17 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADIS16203/PCBZ датащи(HTML) 17 Page - Analog Devices |
|
17 / 28 page ![]() ADIS16203 Rev. 0 | Page 17 of 28 ALM_MAG2 Register Definition Address Default1 Format2 Access 0x23, 0x22 0x0000 N/A R/W 1 Default is valid only until the first register write cycle. 2 Format is established by source of monitored data. The ALM_MAG2 register contains the threshold level for Alarm 2. The contents of this register are nonvolatile. Table 13. ALM_MAG2 Bit Designations Bit Description 15 Greater than Active Alarm Bit. 1: Alarm is active for an output greater than ALM_MAG2 register setting. 0: Alarm is active for an output less than ALM_MAG2 register setting. 14 Not used. 13:0 Data Bits. This number can be either twos complement or straight binary. The format is set by the value being monitored by this function. ALM_SMPL2 Register Definition Address Default1 Format Access 0x27, 0x26 0x0000 Binary R/W 1 Default is valid only until the first register write cycle. The ALM_SMPL2 register contains the sample period information for Alarm 2, when it is set for ROC alarm monitoring. The ROC alarm function averages the change in the output variable over the specified number of samples and compares this change directly to the values specified in the ALM_MAG2 register. The contents of this register are nonvolatile. Table 14. ALM_SMPL2 Bit Designations Bit Description 15:8 Not used 7:0 Data bits ALM_CTRL Register Definition Address Default1 Format Access 0x29, 0x28 0x0000 N/A R/W 1 Default is valid only until the first register write cycle. The ALM_CTRL register contains the alarm control variables. Table 15. ALM_CTRL Bit Designations Bit Value Description 15 Rate of Change (ROC) Enable for Alarm 2 1: ROC is active 0: ROC is inactive 14:12 Alarm 2 Source Selection 000 Alarm disable 001 Alarm source: power supply output 010 Not used 011 Not used 100 Alarm source: auxiliary ADC output 101 Alarm source: temperature sensor output 110 Alarm source: INCL_OUT output 111 Alarm source: INCL_180_OUT output 11 Rate of Change (ROC) Enable for Alarm 1 1: ROC is active 0: ROC is inactive 10:8 Alarm 1 Source Selection 000 Alarm disable 001 Alarm source: power supply output 010 Not used 011 Not used 100 Alarm source: auxiliary ADC output 101 Alarm source: temperature sensor output 110 Alarm source: INCL_OUT output 111 Alarm source: INCL_180_OUT output 7:6 Not used 5 ADF2—Alarm Data Filter 1: Use filtered data for comparison 0: Use instantaneous data for comparison 4 ADF1—Alarm Data Filter 1: Use filtered data for comparison 0: Use instantaneous data for comparison 3 Not used 2 Alarm Output Enable 1: Alarm output enabled 0: Alarm output disabled 1 Alarm Output Polarity 1: Active high 0: Active low 0 Alarm Output Line Select 1: DIO1 0: DIO0 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |