| поискавой системы для электроныых деталей |
|
ZAMC4100GA2R датащи(PDF) 63 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
ZAMC4100GA2R датащи(HTML) 63 Page - Renesas Technology Corp |
|
63 / 156 page ![]() ZAMC4100 Datasheet © 2016 Integrated Device Technology, Inc. 63 January 26, 2016 3.8.3. Half-Bridge Driver Output Diagnostic Check Each half-bridge driver has dedicated diagnostic circuitry that is able to detect open/short failures in the output load. The HB driver diagnostic circuitry is controlled by the HBDDIAG register (Table 3.17 and Table 3.18), and the diagnostic flags are monitored by reading register HBDSTAT. Table 3.19 gives the meaning of the corresponding HBxOSF flags in the HBDSTAT register with respect to the load configuration and the combination of the HBxCSHEN and HBxCSLEN bits of HBDDIAG register, which controls the diagnostic current sources/sinks. Important note: When the diagnostic circuitry is enabled (one of the HBxCSHEN bits or the HBxCSLEN bits is set), then the corresponding over-current protection circuitry is not active. Therefore, enabling the driver when the diagnostic circuitry is enabled is not recommended! Table 3.17 HBDDIAG Register Bits Mapping Name HBDDIAG Bit No 7 6 5 4 3 2 1 0 Bit name Reset 0 0 0 0 0 0 0 0 Access R/W R/W R/W R/W R/W R/W R/W R/W Address 0x07 R/W = Read/Write bit Table 3.18 HBDDIAG Register Bits Description Bit Description 7,5,3,1 HBxCSHEN: 1), 2) High-side current source enable bit for driver x, (x = 4 to 1, for HB4 to HB1 respectively). 1 = The high-side current source of driver x is enabled. 0 = The high-side current source of driver x is disabled. 6,4,2,0 HBxCSLEN: 1), 2) Low-side current source enable bit for driver x, (x = 4 to 1, for HB4 to HB1 respectively). 1 = The low-side current source of driver x is enabled. 0 = The low-side current source of driver x is disabled. 1) In order to keep current consumption as low as possible, the MCU software should disable the current sources before enabling the SLEEP or STANDBY Modes. 2) In the event of an over-temperature event, these current sources are automatically disabled. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |