| поискавой системы для электроныых деталей |
|
LT8607 датащи(PDF) 16 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LT8607 датащи(HTML) 16 Page - Analog Devices |
|
16 / 20 page ![]() LTC9111 16 Rev. 0 For more information www.analog.com ILOAD LTC9111 EN GATE IN GND VREG BULK CAP BUCK CONVERTER 2ND-ORDER FILTER VPDBYPASS EN IN SW 9111 F10 Figure 10. Filtering and Bypass for Dynamic Loads AUXILIARY POWER An auxiliary DC supply can be connected at the LTC9111 OUT pin or down-stream DC/DC converter output with a diode, bypassing the LTC9111 features. In this case, the auxiliary supply is responsible for inrush. FAULT PROTECTION PD Overload Condition In the event of a PD current overload condition, it is antic- ipated that the PSE will limit the port current as mandated by IEEE 802.3cg, causing the voltage at the PD input to collapse. When the PD input voltage drops below the VOFF threshold, the LTC9111 will disable the external MOSFET by pulling the GATE pin to the OUT pin and thus isolate the overload from the cable. PD Input Short If the inputs of the PD are shorted together after appli- cation of power, the high-side polarity correction diodes prevent the PD bulk capacitor from backfeeding through the coupling magnetics, thus protecting the LTC9111. A voltage clamp such as a TVS diode may be necessary to protect the PHY coupling capacitors and magnetics. PD Load Dump If the application produces a large load dump (e.g., the PD current is quickly reduced to zero from a large value), the input voltage to the LTC9111 may overshoot as the power coupling network inductors discharge. The LTC9111 pro- vides a large transient voltage capability of 100V in order to accommodate such transients. If other elements in the system do not have margin to cover such transients, additional application bulk capac- itance can absorb the energy from the charged induc- tance, limiting the voltage stress experienced by the application circuitry. PD Disconnect If a compliant PD is disconnected from a PSE, the 802.3cg standard requires specific limits on the energy that can be back-fed at the connector. In the recommended applica- tion schematic, the high-side rectifier diodes isolate the PD bulk capacitance from the connector, guaranteeing compliance with this specification. PD Connected to Voltage Source The LTC9111 is designed primarily for connection to an 802.3cg complaint, classifying PSE. When a PD is pow- ered directly by an auxiliary power supply, the state will advance to the MDI_POWER2 state and enable the appli- cation, provided the supply voltage exceeds VON for the configured class. Note that the LTC9111 does not imple- ment current limit or circuit breaker functionality. OV Protection for 24V Classes When the LTC9111 is configured for Class 10 through 12 (i.e., CLASSV pin is tied low), an overvoltage protection feature is enabled to protect downstream elements in the application from exposure to excessive voltage. When the input voltage exceeds VOV (40V max), the gate of the external hot swap MOSFET will be turned off, regardless of the port state. APPLICATIONS INFORMATION |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |