L9908 датащи(PDF) 27 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9908 датащи(HTML) 27 Page - STMicroelectronics |
|
27 / 153 page ![]() 2. NVM READ MODE Internal supply and reference voltage/currents are available possibly exceeding spec parametrical ranges. Main logic is out of reset (INT_RST = ’1’, Internal signal). Main functions are disabled: – Gate Driver Supply stage disabled – Half Bridge Gate Drivers stages are in HIZ mode while LS Half Bridge Gate Drivers stages are shutdown (SAFE-HIZ) – Current Monitors chains and monitoring units are disabled – SPI Read is available while SPI Write is disabled In this mode a CRC check on NVM data is first performed: – If no CRC error is detected the NVM content is deployed into main logic register – If a CRC error is detected the related main logic registers are reset to default values (all ‘0’) and NVM_CRC_FAIL flag is set to ‘1’ Note: All parameters are guaranteed and tested in the voltage ranges reported in Table 5 unless otherwise specified. Where not specified the parametrical operating range equals the functional operating range. Table 15. Power up/down timings Symbol Parameter Min Typ Max Unit Notes T_nvm NVM data deploy & CRC duration - - 2 ms Not subject to production test 3. NORMAL MODE Internal supply and reference voltage/currents are available and within spec ranges. Main logic is out of reset (INT_RST = ’1’, Internal signal). Main functions: – Half Bridge Gate Drivers status depends on disable logic assessment (Functional or SAFE_DIS) – Gate Driver Supply stage status depends on configuration – Current Monitors chains and monitoring units status depend on configuration – SPI Read/Write operations are available 4. SAFE OFF MODE Internal supply and reference voltage/currents are available and within spec ranges. Main logic is out of reset (INT_RST = ’1’, Internal signal). Main functions: – Gate Driver Supply stage is disabled – HS and LS state are in SAFE_OFF or SAFE_HIZ depending on fault reaction as described in Table 17 – Current Monitors chains and monitoring units status depend on configuration – SPI Read/Write operations are available 5. SELF TEST MODE Internal supply and reference voltage/currents are available and within spec ranges. Main logic is out of reset (INT_RST = ’1’, Internal signal). Main functions: – Gate Driver Supply stage depends on disable logic assessment – Half Bridge Gate Drivers are disabled (SAFE-DIS) – Current Monitors chains and monitoring units status depend on configuration – SPI Read is available while SPI Write is disabled 6. CONFIG MODE Internal supply and reference voltage/currents are available and within spec ranges. Main logic is out of reset (INT_RST = ’1’, Internal signal). Main functions: – Half Bridge Gate Drivers status depends on disable logic assessment (Functional or SAFE_DIS) – Gate Driver Supply stage status depends on configuration – Current Monitors chains and monitoring units status depend on configuration – SPI Read/Write operations are available Three SPI readable flags are present to read-back the operational state machine status according to the following table: L9908 Device operation state machine DS13546 - Rev 3 page 27/153 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |