| поискавой системы для электроныых деталей |
|
ADFS5758 датащи(PDF) 48 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADFS5758 датащи(HTML) 48 Page - Analog Devices |
|
48 / 75 page ![]() ADFS5758 Data Sheet Rev. 0 | Page 48 of 75 SELECT DEPTH (NUMBER OF CHANNELS) LOAD DESIRED CHANNEL N INTO THE SEQUENCER ENABLE FOR AUTO/ KEY SEQUENCING IS N = DEPTH – 1? DATA[D7:D5] COMMAND[D10:D8] DIAGNOSTIC SELECT[D4:D0] 011 001 DON’T CARE ENABLE AUTOMATIC SEQUENCING N = 0 N = 1 N = 2 N Y DATA[D7:D5] COMMAND[D10:D8] DIAGNOSTIC SELECT[D4:D0] 001 010 VLDO MUX INPUT ADDRESS SELECT CHANNEL 2 WITH VLDO DATA[D7:D5] COMMAND[D10:D8] DIAGNOSTIC SELECT[D4:D0] 001 001 DIE TEMP MUX INPUT ADDRESS SELECT CHANNEL 1 WITH MAIN DIE TEMPERATURE DATA[D7:D5] COMMAND[D10:D8] DIAGNOSTIC SELECT[D4:D0] 001 000 ADC1 PIN MUX INPUT ADDRESS SELECT CHANNEL 0 WITH ADC1 PIN DATA[D7:D5] COMMAND[D10:D8] DIAGNOSTIC SELECT[D4:D0] 000 010 DON’T CARE SELECT A DEPTH OF 3 CHANNELS Figure 87. Example Automatic Sequence Mode Setup for Three ADC Input Nodes ADC Conversion Timing Figure 88 shows an example where autostatus readback mode is enabled. The status register always contains the last completed ADC conversion result, together with the associated mux address, ADC_IP_SELECT. This example is applicable irrespective of the ADC conversion mode in use (key sequencing, automatic sequencing, single immediate conversion, or single key conversion). During the first ADC conversion command shown, the contents of the status register are available on the SDO line. The ADC portion of this data contains the conversion result of the previously converted ADC node (ADC Conversion Result 0), as well as the associated channel address. Assuming another SPI frame is not received while the ADC is busy converting due to Command 1, then the next data to appear on the SDO line contains the associated conversion result, ADC Conversion Result 1. If, however, an SPI frame is received while the ADC is busy, the status register contents available on SDO still contains the previous conversion result and indicates the ADC_BUSY flag is high. Any new ADC conversion instructions received while the ADC_BUSY bit is active are ignored. If using a sequencer mode, the sequencer address is updated after the conversion is complete. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |