| поискавой системы для электроныых деталей |
|
ADE9153AACPZ датащи(PDF) 28 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE9153AACPZ датащи(HTML) 28 Page - Analog Devices |
|
28 / 50 page ![]() ADE9153A Data Sheet Rev. 0 | Page 28 of 50 Overcurrent Indication The ADE9153A monitors the rms½ value on current channels to determine overcurrent events. If an rms½ current is greater than the user configured threshold in the OI_LVL register, the OIx bit in the EVENT_STATUS register is set. The overcurrent event generates an interrupt on the IRQ pin. The OIx_EN bits in the CONFIG3 register select the current channel to monitor for overcurrent events. The OIx bits in the EVENT_STATUS register indicate which current channel exceeded the threshold. The overcurrent value is stored in the OIA and OIB registers. Peak Detection The ADE9153A records the peak value measured on all three channels from the AI_WAV, AV_WAV, and BI_WAV waveforms. The PEAK_SEL bits in the CONFIG3 register allow the user to select which channel to monitor. The IPEAK register stores the peak current value in the IPEAKVAL bits and indicates which phase currents reached the value in the IPPHASE bits. IPEAKVAL is equal to xI_WAV/25. Similarly, VPEAK stores the peak voltage value in the VPEAKVAL bits. VPEAKVAL is equal to AV_WAV/25. After a read, the VPEAK and IPEAK registers reset. Power Factor The power factor calculation, APF, is updated every 1.024 sec. The sign of the APF calculation follows the sign of AWATT. To determine if power factor is leading or lagging, refer to the sign of the total or fundamental reactive energy and the sign of the APF or AWATT value, as shown in Figure 54. The power factor result is stored in 5.27 format. The highest power factor value is 0x07FF FFFF, which corresponds to a power factor of 1. A power factor of −1 is stored as 0xF800 0000. To determine the power factor from the APF register value, use the following equation: Power Factor = APF × 2−27 V I CAPACITIVE: CURRENT LEADS VOLTAGE INDUCTIVE: CURRENT LAGS VOLTAGE WATT VAR 270° LAGGING 90° LAGGING INDUCTIVE: CURRENT LAGS VOLTAGE CAPACITIVE: CURRENT LEADS VOLTAGE WATT (–) VAR (+) QUADRANT II WATT (+) VAR (+) QUADRANT I WATT (–) VAR (–) QUADRANT III WATT (+) VAR (–) QUADRANT IV WATT(+) INDICATES POWER RECEIVED (IMPORTED FROM GRID) WATT(–) INDICATES POWER DELIVERED (EXPORTEDTO GRID) θ2 = 60° PF2 = 0.5 IND θ1 = –30° PF1 = 0.866 CAP Figure 54. WATT and VAR Power Sign for Capacitive and Inductive Loads Temperature The temperature reading is available in the TEMP_RSLT register. To convert the temperature range into Celsius, use the following equation: Temperature (°C) = TEMP_RSLT × (−TEMP_GAIN/217) + (TEMP_OFFSET/25) During the manufacturing of each device, the TEMP_GAIN and TEMP_OFFSET bits of Register TEMP_TRIM are programed. To configure the temperature sensor, program the TEMP_CFG register. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |