26 / 50 page ![]() ADE9153A Data Sheet Rev. 0 | Page 26 of 50 Digital to Frequency Conversion—CFx Output The ADE9153A includes two pulse outputs on the CF1 and CF2 output pins that are proportional to the energy accumulation. The block diagram of the CFx pulse generation is shown in Figure 50. CF2 is multiplexed with ZX and DREADY. Calibration Frequency (CF) Energy Select ion The CFxSEL bits in the CFMODE register select which type of energy to output on the CFx pins. For example, with CF1SEL = 000b and CF2SEL = 100b, CF1 indicates the total active energy, and CF2 indicates the fundamental reactive energy. Configuring the CFx Pulse Width The values of the CFx_LT and the CF_LTMR bits in the CF_LCFG register determine the pulse width. The maximum CFx with threshold (xTHR) = 0x00100000 and CFxDEN = 2 is 78.9 kHz. It is recommended to leave xTHR at the default value of 0x00100000. CFx Pulse Sign The CFxSIGN bits in the PHSIGN register indicate whether the energy in the most recent CFx pulse is positive or negative. The REVPCFx bits in the status register indicate if the CFx polarity changed sign. This feature generates an interrupt on the IRQ pin. Clearing the CFx Accumulator To clear the accumulation in the digital to frequency converter and CFDEN counter, write 1 to the CF_ACC_CLR bit in the CONFIG1 register. The CF_ACC_CLR bit automatically clears itself. POWER QUALITY MEASUREMENTS Zero-Crossing Detection The ADE9153A offers zero-crossing detection on the voltage and both current channels. The current and voltage channel datapaths preceding the zero-crossing detection are shown in Figure 51 and Figure 52. Use the ZX_SRC_SEL bit in the CONFIG0 register to select data before the high-pass filter or after phase compensation to configure the inputs to zero-crossing detection. ZX_SRC_SEL = 0 by default after reset. To provide protection from noise, voltage channel zero-crossing events (ZXAV) do not generate if the absolute value of the LPF1 output voltage is smaller than the threshold, ZXTHRSH. The current channel zero-crossing detection outputs, ZXAI and ZXBI, are active for all input signals levels. Calculate the zero-crossing threshold, ZXTHRSH, from the following equation: ZXTHRSH = 8 2 32 ) ( ) _ ( x n Attenuatio LPF1 Scale Full at WAV V where V_WAV at Full Scale is ±37,282,702 decimal. LPF1 Attenuation is 0.86 at 50 Hz, and 0.81 at 60 Hz. x is the dynamic range below which the voltage channel zero crossing must be blocked. HPF ZERO-CROSSING DETECTION LPF1 AVGAIN PHASE COMP HPFDIS ZX_SRC_SEL AV_WAV ÷32 Figure 51. Voltage Channel Signal Path Preceding Zero-Crossing Detection xIGAIN HPF PHASE COMP INTEGRATOR HPFDIS INTEN_BI xI_WAV ZX_SRC_SEL ZX DETECTION LPF1 ÷32 Figure 52. Current Channel Signal Path Preceding Zero-Crossing Detection |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |