DLP4710AFQL датащи(PDF) 9 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
DLP4710AFQL датащи(HTML) 9 Page - Texas Instruments |
|
9 / 43 page ![]() 9 DLP4710 www.ti.com DLPS125 – NOVEMBER 2018 Product Folder Links: DLP4710 Submit Documentation Feedback Copyright © 2018, Texas Instruments Incorporated (1) The average over time (including storage and operating) that the device is not in the elevated dew point temperature range. (2) Exposure to dew point temperatures in the elevated range during storage and operation should be limited to less than a total cumulative time of CTELR. 6.2 Storage Conditions applicable for the DMD as a component or non-operational in a system MIN MAX UNIT TDMD DMD storage temperature –40 85 °C TDP-AVG Average dew point temperature, (non-condensing)(1) 24 °C TDP-ELR Elevated dew point temperature range, (non-condensing)(2) 28 36 °C CTELR Cumulative time in elevated dew point temperature range 6 Months (1) JEDEC document JEP155 states that 500 V HBM allows safe manufacturing with a standard ESD control process. 6.3 ESD Ratings VALUE UNIT V(ESD) Electrostatic discharge Human body model (HBM), per ANSI/ESDA/JEDEC JS-001(1) ±2000 V (1) The following power supplies are all required to operate the DMD: VDD, VDDI, VOFFSET, VBIAS, and VRESET. All VSS connections are also required. (2) Recommended Operating Conditions are applicable after the DMD is installed in the final product. (3) The functional performance of the device specified in this data sheet is achieved when operating the device within the limits defined by the Recommended Operating Conditions. No level of performance is implied when operating the device above or below the Recommended Operating Conditions limits. (4) All voltage values are with respect to the ground pins (VSS). (5) VOFFSET supply transients must fall within specified max voltages. (6) To prevent excess current, the supply voltage delta |VDDI – VDD| must be less than specified limit. (7) To prevent excess current, the supply voltage delta |VBIAS – VOFFSET| must be less than specified limit. (8) To prevent excess current, the supply voltage delta |VBIAS – VRESET| must be less than specified limit. (9) LS_CLK must run as specified to ensure internal DMD timing for reset waveform commands. (10) Refer to the SubLVDS timing requirements in . 6.4 Recommended Operating Conditions Over operating free-air temperature range (unless otherwise noted) (1) (2) (3) MIN NOM MAX UNIT SUPPLY VOLTAGE RANGE(4) VDD Supply voltage for LVCMOS core logic Supply voltage for LPSDR low-speed interface 1.7 1.8 1.95 V VDDI Supply voltage for SubLVDS receivers 1.7 1.8 1.95 V VOFFSET Supply voltage for HVCMOS and micromirror electrode(5) 9.5 10 10.5 V VBIAS Supply voltage for mirror electrode 17.5 18 18.5 V VRESET Supply voltage for micromirror electrode –14.5 –14 –13.5 V |VDDI–VDD| Supply voltage delta (absolute value)(6) 0.3 V |VBIAS–VOFFSET| Supply voltage delta (absolute value)(7) 10.5 V |VBIAS–VRESET| Supply voltage delta (absolute value)(8) 33 V CLOCK FREQUENCY ƒclock Clock frequency for low speed interface LS_CLK(9) 108 120 MHz ƒclock Clock frequency for high speed interface DCLK(10) 300 540 MHz Duty cycle distortion DCLK 44% 56% SUBLVDS INTERFACE (10) | VID | SubLVDS input differential voltage (absolute value) Figure 8, Figure 9 150 250 350 mV VCM Common mode voltage Figure 8, Figure 9 700 900 1100 mV VSUBLVDS SubLVDS voltage Figure 8, Figure 9 575 1225 mV ZLINE Line differential impedance (PWB/trace) 90 100 110 Ω ZIN Internal differential termination resistance Figure 10 80 100 120 Ω 100-Ω differential PCB trace 6.35 152.4 mm |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |