| поискавой системы для электроныых деталей |
|
DLP4710AFQL датащи(PDF) 22 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
DLP4710AFQL датащи(HTML) 22 Page - Texas Instruments |
|
22 / 43 page ![]() 22 DLP4710 DLPS125 – NOVEMBER 2018 www.ti.com Product Folder Links: DLP4710 Submit Documentation Feedback Copyright © 2018, Texas Instruments Incorporated (1) See Optical Interface and System Image Quality Considerations for more information. (2) See the package mechanical characteristics for details regarding the size and location of the window aperture. (3) The active area of the DLP4710 device is surrounded by an aperture on the inside of the DMD window surface that masks structures of the DMD device assembly from normal view. The aperture is sized to anticipate several optical conditions. Overfill light illuminating the area outside the active array can scatter and create adverse effects to the performance of an end application using the DMD. The illumination optical system should be designed to limit light flux incident outside the active array to less than 10% of the average flux level in the active area. Depending on the particular system's optical architecture and assembly tolerances, the amount of overfill light on the outside of the active array may cause system performance degradation. 6.12 Window Characteristics PARAMETER(1) MIN NOM MAX UNIT Window material designation Corning Eagle XG Window refractive index at wavelength 546.1 nm 1.5119 Window aperture(2) See (2) Illumination overfill(3) See (3) Window transmittance, single-pass through both surfaces and glass Minimum within the wavelength range 420 to 680 nm. Applies to all angles 0° to 30° AOI. 97% Window Transmittance, single-pass through both surfaces and glass Average over the wavelength range 420 to 680 nm. Applies to all angles 30° to 45° AOI. 97% SPACER 6.13 Chipset Component Usage Specification The DLP4710 device is a component of one or more DLP chipsets. Reliable function and operation of the device requires that it be used in conjunction with the other components of the applicable DLP chipset, including those components that contain or implement TI DMD control technology. TI DMD control technology is the TI technology and devices for operating or controlling a DLP DMD. NOTE TI assumes no responsibility for image quality artifacts or DMD failures caused by optical system operating conditions exceeding limits described previously 6.14 Software Requirements CAUTION The DLP4710 DMD has mandatory software requirements. Refer to Software Requirements for TI DLP® Pico™ TRP Digital Micromirror Devices application report for additional information. Failure to use the specified software will result in failure at power up. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |