| поискавой системы для электроныых деталей |
|
ST10F296 датащи(PDF) 197 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST10F296 датащи(HTML) 197 Page - STMicroelectronics |
|
197 / 346 page ![]() Obsolete Product(s) - Obsolete Product(s) ST10F296E CAN modules 197/346 However, considering that real systems typically operate in the presence of electrical disturbances, errors on the CAN bus may occur. If an error is detected, an error flag is transmitted on the bus. If the error is local, only the node which detected it transmits the error flag on the bus; the other nodes receive the error flag and transmit their own error flags as an echo. If the error is global, all nodes detect it within the same bit time and they transmit their own error flags simultaneously. In this way, each node can recognize if the error is local or global simply by detecting whether there is an echo. However, this is possible only if each node can sample the first bit after the error flag has been transmitted. The error flag from an error active node is composed of six dominant bits. In the worst case situation of a bit stuffing error, an additional six dominant bits could be received before the error flag. This means that the first bit after the error flag is the 13th bit after the last synchronization. This bit, must be correctly sampled. Calling tBT the CAN bit time, the maximum time, tS (with correct sampling), between two re- synchronization edges can be expressed as shown in Equation 13. Equation 13 Where tPB2 corresponds to the duration of Phase_Seg2 (PB = phase buffer). Assuming that the two CAN nodes have opposite system clock generator tolerances for their respective system clocks, Equation 14 shows the accumulated phase error, ∆tJ, at the re- synchronization instant. Equation 14 For correct sampling, the accumulated phase error must not lead the re-synchronization edge outside the interval Phase_seg1 + Phase_Seg2. This condition can be expressed as shown in Equation 15. Equation 15 This expression can be translated to a condition for the CAN system clock tolerance, df, as shown in Equation 16. Equation 16 In conclusion, there are two conditions to be satisfied on the CAN system clock tolerance. If the CAN node generates its system clock through a PLL, the maximum clock tolerance allowed must also be a function of the PLL jitter. This results in a more severe quality requirement for the oscillator (crystal or resonator). The phase error introduced by the PLL jitter is a function of the number of clock periods. In particular, the jitter increases with the clock period number up to a maximum saturation value which consists of the long term jitter. Refer to Section 24.8.7: Phase-locked loop (PLL) on page 315 for more details about the ST10F296E PLL jitter. t S 13 t BT t PB2 – × = ∆t S 2df × () 13 t BT × t PB2 – () × = t PB1 2df × () 13 t BT × t Seg2 – () t PB2 < × < df min t PB1 t PB2 , () 213 t BT × t PB2 – () × ⁄ < Obsolete Product(s) - Obsolete Product(s) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |