| поискавой системы для электроныых деталей |
|
PC97338 датащи(PDF) 196 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
PC97338 датащи(HTML) 196 Page - National Semiconductor (TI) |
|
196 / 221 page ![]() 196 www.national.com TABLE 107. Clock Multiplier Encoding Options From this point on, bits 1 and 0 of the CLK register are read-only. The value of the clock source can not be changed, except by a total power-off and power-on cycle. However, the on-chip clock multi- plier can be disabled at any time. 2. If the external clock source is 14.31818 MHz or 24 MHz: — Enable the on-chip clock multiplier. — Poll bit 3 of the CLK register while the clock multiplier is stabilizing. — When bit 3 of CLK is set to 1, go to step 3. If the external clock source is 48 MHz, do not en- able the clock multiplier. 3. Enable any module of the chip. 7.2.3 SCC1 and SCC2 Power-Up The clock signal to the SCCs is controlled by the FER and PTR configuration registers. To restore the clock signal to one or both SCCs, the following must both be true: • The appropriate enable bits, bits 2 and 1 of FER for SCC2 and SCC1, respectively must be set to 1. • The power-down bit, bit 0 of PTR, must be 0. If the on-chip clock multiplier stopped, allow time (maximum 2.4 msec) for multiplier stabilization before sending any data or signaling that the receiver chan- nel is ready. The stabilization period can be sensed by reading the Main Status Register in the FDC, if the FDC is being powered up. (The Request for Master bit (RQM) is not set for approximately 2.4 msec). If the FDC is not powered up but, either one of the SCCs is being powered up, then, software must generate a delay of 2.4 msec. Stabilization of multiplier can also be sensed by putting any of the enabled SCCs into lo- cal loopback mode and sending bytes until they are received correctly. 7.2.4 FDC Power-Up The clock signal to the FDC is controlled by the con- figuration registers, the FDC MODE command and the Data Rate Select Register (DSR). To restore the clock signal to the FDC, both of the fol- lowing conditions must be true: • Bit 3 of FER must be set to 1. • The power-down bit, bit 0 of PTR, must be 0. In addition to these conditions, do one of the following to initiate the recovery from power-down mode: • Read the Main Status Register (MSR) until the RQM bit, bit 7, is set to 1. • Set the software reset bit, bit 7 or the Data Rate Select Register (DSR), to 1. • Write the following to the reset bit, bit 2 or the Dig- ital Output Register (DOR): — Set it to 1. — Clear it to 0. • Read the Data Register and the Main Status Reg- ister until the RQM bit is set to 1. External Clock on Pin X1 (MHz) CLK Register (Index 51h) Valid Clock Multiplier Status Clock Multiplier Enable Chip Clock Source 32 1 0 14.31818 0 = Reset 1 = Stable 10 0 24 1 0 1 48 Always 0 0 1 0 Reserved x x 1 1 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |