| поискавой системы для электроныых деталей |
|
XRT8001IP датащи(PDF) 26 Page - Exar Corporation |
|
|
|||||||||||||||||||||||||||||
XRT8001IP датащи(HTML) 26 Page - Exar Corporation |
|
26 / 48 page ![]() XRT8001 26 Rev. 1.01 Step 3 – Upon reviewing Table 6, write the listed value (under the “Value to Write to D4 – D1 in CR0” register) into the D4 through D1 bit-fields within Command Register CR0, as illustrated below: Command Register CR0 (Address = 0x00) D4 D3 D2 D1 D0 IOC4 IOC3 IOC2 IOC1 PL1EN Value to Write to D4 – D1 in CR0 X Notes: 1. If the user wishes to output a clock signal via the CLK1 output signal, then he/she should also write a “1” into the “PL1EN” bit-field within Command Register CR0. 2. The contents of bit-fields D4 through D1 (within Com- mand Register CR1) are “Don’t Care” 3. If the user wishes to output a clock signal via the CLK2 output signal, then he/she should also write a “1” into the “PL2EN” bit-field within Command Register CR1. This step configures the XRT8001 to operate in the “Fractional T1/E1 Reverse/Master” Mode. Step 4 – Specify the value of “P” (e.g., as in the “P x 56kHz” or “P x 64kHz” clock signal which is to be input via the FIN Reference Clock input). In order to specify the value for “P”, one needs to write in the value of “P - 1” (binary format) into Command Register CR2, as illustrated below: Command Register, CR2 (Address = 0x02) D4 D3 D2 D1 D0 SEL14 SEL13 SEL12 SEL11 SEL10 Value of “P - 1” (in Binary Format). In other words, if one intends to input either a “56kHz” or “64kHz” clock signal via the “FIN” input pin (e.g., where P = 1), then he/she should write a “0” into Command Register CR2. Command Register, CR3 (Address = 0x03) D4 D3 D2 D1 D0 SEL24 SEL23 SEL22 SEL21 SEL20 1 1 1 1 1 Step 6 – Enable any of the following output signals as appropriate: “SYNC”, “CLK1”, “CLK2” and “LOCKDET”. This is accomplished by writing a “1” into the corre- sponding bit-fields, within Command Register CR4, as illustrated below: Command Register CR4, (Address = 0x04) D4 D3 D2 D1 D0 SYNCEN CLK1EN CLK2EN LDETDIS2 LDETDIS1 1 1 1 0 0 6.4 The “E1 to T1 –Forward/Master” Mode When the XRT8001 WAN Clock has been configured to operate in the “E1 to T1 – Forward/Master” Mode, then it will accept a “Q x 2.048MHz” clock signal via the “Reference Clock” input at FIN (pin 3), where “Q” can range anywhere between 1 - 16. In response to this clock signal, the XRT8001 WAN Clock will output a 1.544MHz clock signal via the Clock Output pins (CLK1 and/or CLK2). A simple illustration of the XRT8001 WAN Clock, operating in the “E1 to T1 - Forward/Master” Mode is presented in Figure 16. Step 5 – Write the binary expression “11111” into Command Register CR3. This step is necessary in order to insure proper opera- tion of the XRT8001. This step is also illustrated below: |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |