28 / 41 page ![]() IR36021 DIGITAL POL BUCK CONTROLLER with I2C AND PMBus Interface February 27, 2013 | Rev 3.5 28 Note that when EN is pulled low, the device ramps down Vout. During this time OVP level is equal to the reference voltage (which is ramping down) plus the selected threshold (Table 15). When the soft‐stop is done, the level is switched to fixed OVP level. OVP is disabled whenever Vout is ramped down using I2C or PMBus commands. TABLE 14: OVP OPTIONS OVP_when‐disabled setting When active On IC disabled & IC enabled Off IC enabled Figure 33: External bias caused OVP2, which shuts down both loops (EN2=low), Low‐side MOSFET latched ON for loop2 Figure 34: External bias caused OVP2, which shuts down both loops (EN2=low), MOSFET released when output<0.3V for loop2 Output Under‐voltage Protection (UVP) The IR36021 detects an output under‐voltage condition if the sensed voltage at the CPU is below the user‐ programmable UVP threshold (Table 15) or a fixed 248mV as defined by the VID setting and with or without the load line (Using the fixed or programmable threshold, and the load line term is user selectable). Upon detecting an output under‐voltage condition, the IR36021 responds in the same manner as the OCP, according to the setting selected in Table 16. TABLE 15: OVP/UVP THRESHOLDS Value Threshold 0 150mV 1 200mV 2 250mV 3 325mV 4 350mV 5 375mV 6 400mV 7 500mV Over‐current Protection (OCP) The IR36021 provides a user defined output over‐current protection limit up to a maximum value of 62A per phase per loop. For example, with 2 phases, the OCP maximum would be 62A*2 phases = 124A. To set the OCP current threshold, the current handeling capability of the power stages, the inductor and the input supply should be considered. The controller action in OCP is configurable as shown in Table 16. TABLE 16: OCP & UVP MODE SELECTION OCP/UVP Behavior Mode Per phase OCP Threshold (0 to 62A) Shutdown immediately (cycle power or enable to restart) Hiccup 2X before Shutdown Hiccup indefinitely |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |