46 / 82 page ![]() Functional safety requirements for application software AN3077 46/82 DocID16384 Rev 10 3.15.2 Other requirements Other requirements related to the ADC modules are: ● When an application needs to access the ADC result FIFO, a 32-bit read access shall be performed to verify the channel number on which the conversion has been executed. ● If the ADC analog watchdog function is used for function-safety relevant signal, two analog watchdog channels must monitor the same signal. ● If the Sine Wave Generator (SWG) is used, the ADC (in conjunction with CTU) must be used to check the output signal. 3.16 Temperature sensors There are two temperature sensors: temperature sensor 0 (TSENS_0) mapped to ADC_0 and temperature sensor 1 (TSENS_1) mapped to ADC_1. Mandatory: During power up, the two temperature sensors need to be read by software (TSENS_0 from ADC_0 channel 15, TSENS_1 from ADC_1 channel 15), which must verify that the read values are similar as a means of assessing the functionality of the sensors. However, nothing prohibits reading the temperature sensors during run time if needed. Note: Rationale: A means of assessing functionality of the temperature sensors Mandatory: In addition, the temperature must be acquired from at least one of the temperature sensors by software every FTTI during run time. In case of a fault, software must move the system to a safe state. Note: Rationale: To detect over-temperature faults To set a proper threshold the customer must consider that the maximum operating junction temperature is 150 °C (See the Device_Number data sheet) and the temperature sensor accuracy is 10° C. Note: Implementation hint: See the Device_Number Reference Manual for details on TSENS_x implementation in relation to the ADC. It is important to note that the ADC is part of the temperature measuring safety integrity function. Therefore, it is required that the BIST of the ADC be executed once after boot even if the ADC is not used by the application. Table 12. Software BIST and/or test Software BIST or test Frequency SUPPLY SELF-TEST Once after boot RESISTIVE-CAPACITIVE SELF-TEST Once after boot CAPACITIVE SELF-TEST Once after boot ADC0_SWTEST_REGCRC Once after programming ADC1_SWTEST_REGCRC Once after progamming SIUL_SWTEST_REGCRC Once after progamming ADC_SWTEST_CMP Once for every acquisition |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |