| поискавой системы для электроныых деталей |
|
AD9887/PCB датащи(PDF) 36 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9887/PCB датащи(HTML) 36 Page - Analog Devices |
|
36 / 40 page ![]() REV. 0 –36– AD9887 1B 7–0 Test Register Must be set to 10H for proper operation. 1C 7–2 Test Bits Must be set to 6FH for proper operation. 1C 1 Output Format Mode Select A bit that configures the output data in 4:2:2 mode. This mode can be used to reduce the number of data lines used from 24 down to 16 for applications using YUV, YCbCr, or YPbPr graphics signals. A timing diagram for this mode is shown on page 22. Recommended input and output con- figurations are shown in Table LI. In 4:2:2 mode, the red and blue channels can be interchanged to help satisfy board layout or timing requirements, but the green channel must be configured for Y. Table LI. 4:2:2 Output Mode Select Select Output Mode 1 4:4:4 1 4:2:2 Table LII. 4:2:2 Input/Output Configuration Input Output Channel Connection Format Red V U/V Green Y Y Blue U High Impedance 1C 1–0 Test Bits Must be set to default. 2-WIRE SERIAL CONTROL PORT A 2-wire serial interface control interface is provided. Up to four AD9887 devices may be connected to the 2-wire serial interface, with each device having a unique address. The 2-wire serial interface comprises a clock (SCL) and a bidi- rectional data (SDA) pin. The Analog Flat Panel Interface acts as a slave for receiving and transmitting data over the serial interface. When the serial interface is not active, the logic levels on SCL and SDA are pulled HIGH by external pull-up resistors. Data received or transmitted on the SDA line must be stable for the duration of the positive-going SCL pulse. Data on SDA must change only when SCL is LOW. If SDA changes state while SCL is HIGH, the serial interface interprets that action as a start or stop sequence. There are five components to serial bus operation: • Start Signal • Slave Address Byte • Base Register Address Byte • Data Byte to Read or Write • Stop Signal When the serial interface is inactive (SCL and SDA are HIGH) communications are initiated by sending a start signal. The start signal is a HIGH-to-LOW transition on SDA while SCL is HIGH. This signal alerts all slaved devices that a data transfer sequence is coming. The first eight bits of data transferred after a start signal comprising a 7-bit slave address (the first seven bits) and a single R/ W bit (the eighth bit). The R/ W bit indicates the direction of data transfer, read from (1) or write to (0) the slave device. If the transmitted slave address matches the address of the device (set by the state of the SA1-0 input pins in Table LIII, the AD9887 acknowledges by bringing SDA LOW on the 9th SCL pulse. If the addresses do not match, the AD9887 does not acknowledge. Table LIII. Serial Port Addresses Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 A6 A5 A4 A3 A2 A1 A0 (MSB) 1 0 01100 1 0 01101 1 0 01110 1 0 01111 Data Transfer via Serial Interface For each byte of data read or written, the MSB is the first bit of the sequence. If the AD9887 does not acknowledge the master device during a write sequence, the SDA remains HIGH so the master can generate a stop signal. If the master device does not acknowledge the AD9887 during a read sequence, the AD9887 interprets this as “end of data.” The SDA remains HIGH so the master can generate a stop signal. Writing data to specific control registers of the AD9887 requires that the 8-bit address of the control register of interest be written after the slave address has been established. This control register address is the base address for subsequent write operations. The base address autoincrements by one for each byte of data written after the data byte intended for the base address. If more bytes are transferred than there are available addresses, the address will not increment and remain at its maximum value of 1Dh. Any base address higher than 1Dh will not produce an acknowledge signal. Data is read from the control registers of the AD9887 in a similar manner. Reading requires two data transfer operations: The base address must be written with the R/ W bit of the slave address byte LOW to set up a sequential read operation. Reading (the R/ W bit of the slave address byte HIGH) begins at the previously established base address. The address of the read register autoincrements after each byte is transferred. To terminate a read/write sequence to the AD9887, a stop sig- nal must be sent. A stop signal comprises a LOW-to-HIGH transition of SDA while SCL is HIGH. A repeated start signal occurs when the master device driving the serial interface generates a start signal without first generat- ing a stop signal to terminate the current communication. This is used to change the mode of communication (read, write) between the slave and master without releasing the serial inter- face lines. Serial Interface Read/Write Examples Write to one control register ➥Start signal ➥Slave Address byte (R/W bit = LOW) ➥Base Address byte ➥Data byte to base address ➥Stop signal |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |