| поискавой системы для электроныых деталей |
|
WM8311 датащи(PDF) 77 Page - Wolfson Microelectronics plc |
|
|
|||||||||||||||||||||||||||||
WM8311 датащи(HTML) 77 Page - Wolfson Microelectronics plc |
|
77 / 302 page ![]() Pre-Production WM8311 w PP, May 2012, Rev 3.1 77 The DC-DC3 Buck Converter has a selectable overvoltage protection feature, controlled by DC3_OVP. This affects the converter response when DC3 is enabled or when its output voltage is increased. When the overvoltage protection is enabled, there is less overshoot in the output voltage, but some oscillation may occur as the voltage settles. This function should only be enabled if steep load transients are present on the output of DC-DC3 and if the voltage overshoot is critical. 15.11 MONITORING AND FAULT REPORTING Each of the DC-DC Converters (1 to 4) and LDOs (1 to 5 and 7) is monitored for voltage accuracy and fault conditions. An undervoltage condition is detected if the voltage falls below the required level by more than a pre-determined tolerance. If an undervoltage condition occurs, then this is indicated using the corresponding status bit(s) defined in Section 15.12.6. An undervoltage condition also triggers an Undervoltage Interrupt (see Section 15.13). Additional actions to shut down the converter or perform a Device Reset may also be selected. The Internal LDO (LDO13) is also monitored for voltage accuracy and fault conditions. An undervoltage condition in LDO13 is indicated using the INTLDO_UV_STS bit. This undervoltage condition also causes an OFF transition to be scheduled, as described in Section 11.3. DC-DC Converters 1 and 2 are monitored for overvoltage conditions. An overvoltage condition is set if the voltage is more than 100mV above the required level. If an overvoltage condition occurs, then this is indicated using the corresponding status bit(s). Note that there is no Interrupt or other selectable response to an overvoltage condition. The current draw on DC-DC Converters 1 and 2 can be monitored against user-programmable thresholds in order to detect a high current condition. This feature is enabled using DCm_HC_IND_ENA and the current threshold is set using DCm_HC_THR. Note that the high current threshold is not the same as the maximum current capability of the DC-DC Converters, but is set according to the application requirements. If a high current condition occurs, then this is indicated using the corresponding status bit(s). A high current condition also triggers a High Current Interrupt (see Section 15.13). 15.12 POWER MANAGEMENT REGISTER DEFINITIONS 15.12.1 DC-DC CONVERTER AND LDO REGULATOR ENABLE The Enable and Status register bits for the DC-DC Converters and LDO Regulators are defined in Table 34. ADDRESS BIT LABEL DEFAULT DESCRIPTION R16464 (4050h) DCDC Enable 3:0 DCm_ENA 0 DC-DCm Enable request 0 = Disabled 1 = Enabled (Note that the actual status is indicated in DCm_STS) R16465 (4051h) LDO Enable 10:0 LDOn_ENA 0 LDOn Enable request 0 = Disabled 1 = Enabled (Note that the actual status is indicated in LDOn_STS) R16466 (4052h) DCDC Status 3:0 DCm_STS 0 DC-DCm Status 0 = Disabled 1 = Enabled R16467 (4053h) LDO Status 10:0 LDOn_STS 0 LDOn Status 0 = Disabled 1 = Enabled Notes: 1. n is a number (1-5, 7, 11) that identifies the individual LDO Regulator. 2. m is a number between 1 and 4 that identifies the individual DC-DC Converter. Table 34 DC-DC Converter and LDO Regulator Control |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |