53 / 302 page ![]() Pre-Production WM8311 w PP, May 2012, Rev 3.1 53 The FLL output frequency is generated according to the following equation: FOUT = (FVCO / FLL_OUTDIV) The FLL operating frequency, FVCO is set according to the following equation: FVCO = (FREF x N.K x FLL_FRATIO) See Table 20 for the coding of the FLL_OUTDIV and FLL_FRATIO fields. FREF is the input frequency, as determined by FLL_CLK_REF_DIV. FVCO must be in the range 90-100 MHz. Frequencies outside this range cannot be supported. Note that the output frequencies that do not lie within the ranges quoted above cannot be guaranteed across the full range of device operating temperatures. In order to follow the above requirements for FVCO, the value of FLL_OUTDIV should be selected according to the desired output FOUT. The divider, FLL_OUTDIV, must be set so that FVCO is in the range 90-100MHz. The available divisions are integers from 4 to 64. Some typical settings of FLL_OUTDIV are noted in Table 18. OUTPUT FREQUENCY FOUT FLL_OUTDIV 2.8125 MHz - 3.125 MHz 011111 (divide by 32) 3.75 MHz - 4.1667 MHz 010111 (divide by 24) 5.625 MHz - 6.25 MHz 001111 (divide by 16) 11.25 MHz - 12.5 MHz 000111 (divide by 8) 18 MHz - 20 MHz 000100 (divide by 5) 22.5 MHz - 25 MHz 000011 (divide by 4) Table 18 Selection of FLL_OUTDIV The value of FLL_FRATIO should be selected as described in Table 19. REFERENCE FREQUENCY FREF FLL_FRATIO 1MHz - 13.5MHz 000 (divide by 1) 256kHz - 1MHz 001 (divide by 2) 128kHz - 256kHz 010 (divide by 4) 64kHz - 128kHz 011 (divide by 8) Less than 64kHz 100 (divide by 16) Table 19 Selection of FLL_FRATIO In order to determine the remaining FLL parameters, the FLL operating frequency, FVCO, must be calculated, as given by the following equation: FVCO = (FOUT x FLL_OUTDIV) The value of FLL_N and FLL_K can then be determined as follows: N.K = FVCO / (FLL_FRATIO x FREF) See Table 20 for the coding of the FLL_OUTDIV and FLL_FRATIO fields. Note that FREF is the input frequency, after division by FLL_CLK_REF_DIV, where applicable. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |