| поискавой системы для электроныых деталей |
|
M32C/8A датащи(PDF) 197 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
M32C/8A датащи(HTML) 197 Page - Renesas Technology Corp |
|
197 / 372 page ![]() M32C/8A Group 16. Three-Phase Motor Control Timer Function Rev.1.00 Jul 15, 2007 Page 180 of 352 REJ09B0385-0100 Figure 16.2 INVC0 Register b7 b6 b5 b4 b1 b2 b3 Three-Phase PWM Control Register 0(1) Symbol INVC0 Address 0308h Bit Symbol Bit Name RW INV00 After Reset 00h RW b0 Function ICTB2 count condition select bits INV01 RW RW b1 b0 0 0: 0 1: 1 0: Timer B2 underflow at the rising edge of the timer A1 reload control signal(2) (every odd-numbered timer B2 underflow) 1 1: Timer B2 underflow at the falling edge of the timer A1 reload control signal(2) (every even-numbered timer B2 underflow) INV02 Three-phase motor control timer function enable bit(3) 0: Three-phase motor control timer function not used 1: Three-phase motor control timer function used(4,5) INV03 Three-phase motor control timer output control bit 0: Three-phase motor control timer output disabled(5,6) 1: Three-phase motor control timer output enabled Modulation mode select bit(9) 0: Triangular wave modulation mode 1: Sawtooth wave modulation mode(10) INV06 RW RW RW INV04 Upper and lower arm simultaneous turn-on disable bit 0: Simultaneous turn-on enabled 1: Simultaneous turn-on disabled INV05 Upper and lower arm simultaneous turn-on detect flag 0: Not detected 1: Detected (7) RO Software trigger select bit Transfer trigger is generated when the INV07 bit is set to 1. Trigger for the dead time timer is also generated when the INV06 bit is set to 1. This bit is read as 0. INV07 RW NOTES: 1. Set the INVC0 register after the PRC1 bit in the PRCR register is set to 1 (write enable). Set bits INV06 and INV02 to INV00 while timers A1,A2, A4, and B2 are stopped. 2. Set the INV01 bit to 1 after setting a value to the ICTB2 register. Also, when the INV01 bit is set to 1, set the timer A1 count start bit to 1 prior to the first timer B2 underflow. 3. Set pins after the INV02 bit is set to 1. Refer to the table, Pin settings when using three-phase motor control timer function . 4. Set the INV02 bit to 1 to operate the dead time timer, U-, V-, and W-phase output control circuits, and ICTB2 counter. 5. When the INV03 bit is set to 0 and the INV02 bit to 1, pins U, U, V, V, W, and W (including when other output functions are assiged to these pins) are all placed in high-impedance states. 6. The INV03 bit becomes 0 when one of the following occurs: -Reset -The both upper and lower arms output the active level signals at the same time while the INV04 bit is set to 1 -The INV03 bit is set to 0 by program -Signal applied to the NMI pin changes from "H" to "L" (while an "L" is applied to the NMI pin, the INV03 bit cannot be set to 1). 7. The INV05 bit cannot be set to 1 by program. To set the INV05 bit to 0, write a 0 to the INV04 bit. Timer B2 underflow |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |