143 / 271 page ![]() Rev.1.40 Oct 06, 2004 page 143 of 269 M306V2ME-XXXFP, M306V2EEFP Item Standard Clock Mode High-speed Clock Mode Setup time 5.35 µs (53.5 cycles) 1.85 µs (18.5 cycles) Hold time 4.9 µs (49 cycles) 2.4 µs (24 cycles) Set/reset time for BB flag 3.75 µs (37.5 cycles) 0.85 µs (8.5 cycles) (7) START condition generation method When the ESO bit of the I2Ci control register is “1,” execute a write instruction to the I2Ci status register to set the MST, TRX and BB bits to “1.” A START condition will then be generated. After that, the bit counter becomes “0002” and an SCL for 1 byte is output. The START condition generation timing and BB bit set timing are different in the standard clock mode and the high-speed clock mode. Refer to Figure 2.11.42 for the START condition generation timing diagram, and Table 2.11.13 for the START condition/STOP condition generation timing table. (8) STOP condition generation method When the ESO bit of the I2Ci control register is “1,” execute a write instruction to the I2Ci status register for setting the MST bit and the TRX bit to “1” and the BB bit to “0”. A STOP condition will then be generated. The STOP condition generation timing and the BB flag reset timing are different in the standard clock mode and the high-speed clock mode. Refer to Figure 2.11.43 for the STOP condition generation timing diagram, and Table 2.11.13 for the START condition/STOP condition generation timing table. Fig. 2.11.42 START condition generation timing diagram Fig. 2.11.43 STOP condition generation timing diagram Table 2.11.13 START condition/STOP condition generation timing table Note: Absolute time at BCLK = 10 MHz. The value in parentheses denotes the number of BCLK cycles. I2Ci status register write signal Set time for BB flag Hold time Setup time SCL SDA BB flag I2Ci status register write signal Reset time for BB flag Hold time Setup time SCL SDA BB flag |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |