| поискавой системы для электроныых деталей |
|
MK50H27PLCC датащи(PDF) 27 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
MK50H27PLCC датащи(HTML) 27 Page - STMicroelectronics |
|
27 / 56 page ![]() T3 ALIGNED TIMEOUT TIMER PERIOD. T3 determines the maximum time the MK50H27 will wait in the ALIGNED state before signalling link failure. Represented as two’s complement. T4n NORMAL PROVING PERIOD. T4n determines the length of the normal proving period as defined in CCITT Q.703. Represented as two’s complement. T4e EMERGENCY PROVING PERIOD. T4e determines the length of the emergency proving period as defined in CCITT Q.703. Represented as two’s complement. T5 BUSY TRANSMIT PERIOD. T5 determines the amount of time the MK50H27 will wait between transmissions of status indication ”B” while in congestion state. Represented as two’s complement. T6 EXCESSIVE BUSY TIMER PERIOD. T6 determines the amount of time the MK50H27 will allow a remote site to remain in the congested state before signalling link failure. Represented as two’s complement. T7 EXCESSIVE ACKNOWLEDGE TIMER PERIOD. T7 determines the maximum amount of time the MK50H27 will wait for an expected acknowledgement of an MSU before signalling link failure. Repre- sented as two’s complement. TP TRANSMIT POLLING PERIOD. This scaled timer determines the length of time between transmit signal unit checks. Unless TDMD (see CSR0) is set or a signal unit is received on the link, no at- tempt to transmit a signal unit in the transmit descriptor ring is made until TP expires. At TP expiration all transmit signal units in the transmit descriptor ring are sent. Represented as two’s complement. RESERVED/ 16-bit Scaler Can be programmed as all zeroes for compatibliity with existing MK50H27 applications. However, if ESEN=1 (CSR2<14>), then this field is de- fined as a 16-bit scaler for all of the timers, and it will be used instead of the Scaler at IADR+02. This prescaler is incremented once every 32 system clock pulses. When it reaches zero the timers are incre- mented and the prescaler is reset. This field is interpreted as the two’s complement of the prescaler period. This 16-bit scaler is NOT multiplied by 16 when read into the MK50H27. Timers For Optional TTC JT-Q703 Compliance Tf FISU Sending Interval timer. This timer, located at IADR + 144 will determine the amount of time between transmission of FISUs when in TTC JT-Q703 compliant mode (CSR2<08> JSS7E=1). Represented as two’s complement. Ts SIOS Sending Interval timer. This timer, located at IADR + 146 will determine the amount of time between transmission of SIOS signal units when in TTC JT-Q703 compliant mode (CSR2<08> JSS7E=1). Represented as two’s complement. To SIO Sending Interval timer. This timer, located at IADR + 148 will determine the amount of time between transmission of SIOsignal units when in TTC JT-Q703 compliant mode (CSR2<08> JSS7E=1). Repre- sented as two’s complement. Ta SIE Sending Interval timer. This timer, located at IADR + 150 will determine the amount of time between transmission of SIE signal units when in TTC JT-Q703 compliant mode (CSR2<08> JSS7E=1). Repre- sented as two’s complement. Note: The Tf, Ts, To, & Ta timers are only active and valid when JSS7E=1 (CSR2<08>). MK50H27 27/56 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |