Back Button CHR71000 Datasheet HTML 32Page - ams-OSRAM AG CHR71000 Datasheet HTML 33Page - ams-OSRAM AG CHR71000 Datasheet HTML 34Page - ams-OSRAM AG CHR71000 Datasheet HTML 35Page - ams-OSRAM AG CHR71000 Datasheet HTML 36Page - ams-OSRAM AG CHR71000 Datasheet HTML 37Page - ams-OSRAM AG CHR71000 Datasheet HTML 38Page - ams-OSRAM AG CHR71000 Datasheet HTML 39Page - ams-OSRAM AG CHR71000 Datasheet HTML 40Page - ams-OSRAM AG Next Button
Zoom Inzoom in Zoom Outzoom out
 36 / 54 page
background image
CHR71000
Functional description
Datasheet • PUBLIC • Document Feedback
DS000427 • v2-01 • 2026-Mar-18
36 / 54
/
7.4.3
Subsampling
Next to windowing, the sensor also supports sub-sampling in y. Sub-sampling in y can be
enabled with a register upload (it's off by default). When sub-sampling is enabled, only every
8th row is read out. The window size in y is divided by 8. Sub-sampling is not possible in the x-
direction because of the parallel output structure (8 columns read out in parallel). Sub-
sampling in x-direction is actually achieved by ignoring data on some outputs (these outputs
can be put in standby in such case).
Information:
• Note that the integration time is specified as a number of line times. If the window size in x is
changed, the time it takes to read out a line also changes. This means that changing the
window size in x also changes the actual integration time.
7.4.4
Invalid frames
A frame is not started if it has invalid settings. Invalid settings are:
Start address is bigger than end address in y direction.
Start address is bigger than end address in x direction.
Start address and/ or end address out of range in y direction.
Start address and/ or end address out of range in x direction.
Integration time setting is 0
If invalid settings are set through a register upload, the next frame is not started and the sensor
returns to idle state.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com