27 / 62 page ![]() Power_LSB=20Current_LSB Power_LSB=400 10 ´ -6 Max_Current=Current_LSB 32767 ´ Max_Current=0.65534 Max_ShuntVoltage=Max_Current_Before_Overflow R ´ SHUNT Max_ShuntVoltage=0.32 MaximumPower=Max_Current_Before_Overflow V ´ BUS_MAX MaximumPower=20.48 Corrected_Full_Scale_Cal=trunc Cal MeasShuntCurrent TMP513_Current ´ Corrected_Full_Scale_Cal=3548 TMP512 TMP513 www.ti.com SBOS491A – JUNE 2010 – REVISED MAY 2011 6. Calculate the Power LSB with Equation 10. Equation 10 shows a general formula; because the bus voltage measurement LSB is always 4mV, the power formula reduces to the calculated result. (10) 7. Compute the maximum current and shunt voltage values (before overflow), as shown by Equation 11 and Equation 12. Note that both Equation 11 and Equation 12 involve an If - then condition: (11) If Max_Current ≥ MaxPossible_I then Max_Current_Before_Overflow = MaxPossible_I Else Max_Current_Before_Overflow = Max_Current End If (Note that Max_Current is greater than MaxPossible_I in this example.) Max_Current_Before_Overflow = 0.64 (12) If Max_ShuntVoltage ≥ VSHUNT_MAX Max_ShuntVoltage_Before_Overflow = VSHUNT_MAX Else Max_ShuntVoltage_Before_Overflow= Max_ShuntVoltage End If (Note that Max_ShuntVoltage is greater than VSHUNT_MAX in this example.) Max_ShuntVoltage_Before_Overflow = 0.32 8. Compute the maximum power with Equation 13. (13) 9. (Optional second Calibration step.) Compute corrected full-scale calibration value based on measured current. TMP513_Current = 0.63484 MeaShuntCurrent = 0.55 (14) Figure 32 illustrates how to perform the same procedure discussed in this example using the automated TMP512/13EVM software. Note that the same numbers used in this nine-step example are used in the software example. Note also that Figure 32 illustrates which results correspond to which step (for example, the information entered in Step 1 is enclosed in a box in Figure 32 and labeled). Copyright © 2010–2011, Texas Instruments Incorporated 27 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |