20 / 62 page ![]() TMP512 TMP513 SBOS491A – JUNE 2010 – REVISED MAY 2011 www.ti.com HIGH-SPEED MODE SENSOR FAULT In order for the two-wire bus to operate at frequencies The TMP512/13 can sense an open circuit. above 400kHz, the master device must issue a Short-circuit conditions return a value of –256°C. The High-Speed mode (Hs-mode) master code (0000 detection circuitry consists of a voltage comparator 1xxx) as the first byte after a START condition to that trips when the voltage at DXP exceeds (V+) – switch the bus to high-speed operation. The 0.6V (typical). The comparator output is continuously TMP512/13 do not acknowledge this byte, but switch checked during a conversion. If a fault is detected, the input filters on SDA and SCL and the output filter the OPEN bit (bit 0) in the temperature result register on SDA to operate in Hs-mode, allowing transfers at is set to '1' and the rest of the register bits should be up to 3.4MHz. After the Hs-mode master code has ignored. been issued, the master transmits a START condition When not using the remote sensor with the to a two-wire slave address that initiates a data TMP512/13, the DXP and DXN inputs must be transfer operation. The bus continues to operate in connected together to prevent meaningless fault Hs-mode until a STOP condition occurs on the bus. warnings. Upon receiving the STOP condition, the TMP512/13 switch the input and output filters back to Fast mode UNDERVOLTAGE LOCKOUT operation. The TMP512/13 sense when the power-supply POWER-UP CONDITIONS voltage has reached a minimum voltage level for the ADC to function. The detection circuitry consists of a Power-up conditions apply to a software reset via the voltage comparator that enables the ADC after the RST bit (bit 15) in the Configuration Register, or the power supply (V+) exceeds 2.7V (typical). The two-wire bus General Call Reset. At device power up, comparator output is continuously checked during a all Status bits are masked, and the SMBus Alert conversion. The TMP512/13 do not perform a function is disabled. All watchdog outputs default to temperature conversion if the power supply is not active low and transparent (non-latched) modes. valid. The PVLD bit (see Status Register; Local Temperature Reset Register; Remote Temperature SHUTDOWN MODE Reset 1, 2 and 3 Registers) of the individual Local/Remote Temperature Result Registers are set The TMP512/13 shutdown mode of operation allows to '1' and the temperature result may be incorrect. the user flexibility to shut down the shunt/bus voltage measurement and the temperature measurement functions individually. TEMPERATURE AVERAGING To shut down the shunt/bus voltage measurement The TMP512/13 average the input diode voltages function immediately, set bits 2 through 0 in that determine the remote temperature by sampling Configuration Register 1 (00h) to '000' respectively. multiple times throughout a conversion. The To shut down the shunt/bus voltage measurement temperature result can be extracted from four after the end of the current conversion, set bits 2 different VBE readings and is sampled 600 times in through 0 in Configuration Resister 1 (00h) to '100' 130ms (max). Each VBE voltage is sampled 150 times respectively. through integration capacitors that average the results throughout the conversion time. A delta-sigma To shut down the temperature measurement function ( ΔΣ) modulator and digital filter integrate the VBE immediately, set bits 15 through 11 in Configuration voltages and create a sync filter averaging system. In Register 2 (01h) to '00000' respectively. To shut addition, a low-pass filter is present at the input of the down the temperature measurement after the end of converter with a cutoff frequency of 65kHz. This the current conversion, set bit 15 in Configuration integrating topology offers superior noise immunity. Register 2 (01h) to '0'. FILTERING ONE-SHOT COMMAND Remote junction temperature sensors are usually For the TMP512/13, when the temperature core is in implemented in a noisy environment. Noise is shutdown and the voltage core is in triggered mode, a frequently generated by fast digital signals and if not single conversion is started on all enabled channels filtered properly will induce errors that can corrupt by writing a '1' to the OS bit in Configuration Register temperature measurements. The TMP512/13 have a 1. This write operation starts one conversion; the built-in 65kHz filter on the inputs of DXP and DXN to TMP512/13 returns to shutdown mode when that minimize the effects of noise. However, a bypass conversion completes. At the end of the conversion, capacitor placed differentially across the inputs of the the Conversion Ready flags (bit 6 and bit 5) in the remote temperature sensor is recommended to make Status Register are set to indicate end of conversion. the application more robust against unwanted coupled signals. The value of this capacitor should be 20 Copyright © 2010–2011, Texas Instruments Incorporated |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |