| поискавой системы для электроныых деталей |
|
TMP512 датащи(PDF) 15 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMP512 датащи(HTML) 15 Page - Texas Instruments |
|
15 / 62 page ![]() V V = - BE2 BE1 nkT q I I 2 1 ( In n = eff 1.008 300 (300 N ) - ADJUST ´ N 300 ADJUST - = 300 1.008 n eff ´ ( ´ Power Register Current Register Two-Wire Interface Voltage Register ADC GND GPIO DXP1 DXN1 DXP2 DXN2 ADC Low-Pass Filter MUX DXP3 DXN3 V IN+ V IN- Current Shunt Load Filter C V+ Subregulator 3.3V Internal Diode Temperature Sensor A0 ALERT SDA SCL SMBus Controller 3.3V Supply TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491A – JUNE 2010 – REVISED MAY 2011 n-FACTOR CORRECTION REGISTER twos-complement format, yielding an effective data range from –128 to +127. The n-factor value may be The TMP512/13 allow for a different n-factor value to written to and read from pointer address 16h for be used for converting remote channel remote channel 1, pointer address 17h for remote measurements to temperature. The remote channel channel 2, and pointer address 18h for remote uses sequential current excitation to extract a channel 3. The register power-on reset value is 00h, differential VBE voltage measurement to determine thus having no effect unless the register is written to. the temperature of the remote transistor. Equation 1 describes this voltage and temperature. BUS OVERVIEW The device that initiates the transfer is called a (1) master, and the devices controlled by the master are slaves. The bus must be controlled by a master The value n in Equation 1 is a characteristic of the device that generates the serial clock (SCL), controls particular transistor used for the remote channel. The the bus access, and generates START and STOP power-on reset value for the TMP512/13 is n = 1.008. conditions. The value in the n-Factor Correction Register may be used to adjust the effective n-factor according to To address a specific device, the master initiates a Equation 2 and Equation 3. START condition by pulling the data signal line (SDA) from a HIGH to a LOW logic level while SCL is HIGH. All slaves on the bus shift in the slave address byte (2) on the rising edge of SCL, with the last bit indicating whether a read or write operation is intended. During the ninth clock pulse, the slave being addressed (3) responds to the master by generating an The n-factor value must be stored in Acknowledge and pulling SDA LOW. Figure 23. Typical Application Circuit Copyright © 2010–2011, Texas Instruments Incorporated 15 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |