19 / 62 page ![]() SCL SDA t (LOW) t R t F t (HDSTA) t (HDSTA) t (HDDAT) t (BUF) t (SUDAT) t (HIGH) t (SUSTA) t (SUSTO) P S S P TMP512 TMP513 www.ti.com SBOS491A – JUNE 2010 – REVISED MAY 2011 TIMING DIAGRAMS Data Transfer: The number of data bytes transferred between a START and a STOP condition is not Figure 28 describes the timing operations on the limited and is determined by the master device. The TMP512/13. Parameters for Figure 28 are defined in receiver acknowledges data transfer. Table 2. Bus definitions are: Acknowledge: Each receiving device, when Bus Idle: Both SDA and SCL lines remain high. addressed, is obliged to generate an Acknowledge bit. A device that acknowledges must pull down the Start Data Transfer: A change in the state of the SDA line during the Acknowledge clock pulse in such SDA line, from high to low, while the SCL line is high, a way that the SDA line is stable low during the high defines a START condition. Each data transfer period of the Acknowledge clock pulse. Setup and initiates with a START condition. Denoted as S in hold times must be taken into account. On a master Figure 28. receive, data transfer termination can be signaled by Stop Data Transfer: A change in the state of the the master generating a Not-Acknowledge on the last SDA line from low to high while the SCL line is high byte that has been transmitted by the slave. defines a STOP condition. Each data transfer terminates with a repeated START or STOP condition. Denoted as P in Figure 28. Figure 28. Two-Wire Timing Diagram Table 2. Timing Characteristics for Figure 28 FAST MODE HIGH-SPEED MODE PARAMETER MIN MAX MIN MAX UNIT SCL Operating Frequency f(SCL) 0.001 0.4 0.001 3.4 MHz Bus Free Time Between STOP and START Condition t(BUF) 600 160 ns Hold time after repeated START condition. After this period, the first clock t(HDSTA) 100 100 ns is generated. Repeated START Condition Setup Time t(SUSTA) 100 100 ns STOP Condition Setup Time t(SUSTO) 100 100 ns Data Hold Time t(HDDAT) 0(1) 0(2) ns Data Setup Time t(SUDAT) 100 10 ns SCL Clock LOW Period t(LOW) 1300 160 ns SCL Clock HIGH Period t(HIGH) 600 60 ns Clock/Data Fall Time tF 300 160 ns Clock/Data Rise Time tR 300 160 ns for SCL ≤ 100kHz tR 1000 (1) For cases with fall time of SCL less than 20ns and/or the rise or fall time of SDA less than 20ns, the hold time should be greater than 20ns. (2) For cases with a fall time of SCL less than 10ns and/or the rise or fall time of SDA less than 10ns, the hold time should be greater than 10ns. Copyright © 2010–2011, Texas Instruments Incorporated 19 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |