| поискавой системы для электроныых деталей |
|
80221 датащи(PDF) 53 Page - LSI Computer Systems |
|
|
|||||||||||||||||||||||||||||
80221 датащи(HTML) 53 Page - LSI Computer Systems |
|
53 / 91 page ![]() 80220/80221 4-53 MD400159/E 53 the address is desired, then a 50K resistor to GND must be added as shown in Figure 15b. If no LED's are needed on the LED outputs, the selection of addresses can be done as shown in Figure 15c. If a high address is desired, the pin should be left floating and the internal pullup will pull the pin high during power-on reset time and latch in a high address value. If a low address is desired, then the MDINT and PLED[3:0] output pins should be tied either directly to GND or through an optional 50K resistor to GND. PLED3 should always be tied through a 50K resistor to GND since it has both pullup and pulldown capability. The optional 50K resistor also allows the MDINT and PLED[2:0] pins to be used as digital outputs under normal conditions. Note that the MDA[4:0] addresses are inverted inside the 80220/80221 before going to the MI serial port block. This means that the MDA[4:0] pins would have to be pin strapped to 11111 externally in order to successfully match the MI physical address bits PHYAD[4:0]=00000 internally. Figure 15. Serial Device Port Address Selection 5.11 LONG CABLE IEEE 802.3 specifies that 10BaseT and 100BaseTX oper- ate over twisted pair cable lengths of between 0-100 meters. The squelch levels can be reduced by 4.5 dB if the receive level adjust bit is appropriately set in the MI serial port Configuration 1 register, which will allow the 80220/ 80221 to operate with up to 150 meters of twisted pair cable. The equalizer is already designed to accommodate between 0-125 meters of cable. 5.12 AUTOMATIC JAM The 80220/80221 has an automatic JAM generation fea- ture which automatically transmits a JAM packet when receive activity is detected. This feature is primarily de- signed to give the user a means to easily implement half duplex flow control. In a typical application, a watermark signal from a system FIFO or memory would be tied directly to the JAM pin. When the system FIFO is nearly full and more data is incoming from receiver, the device will automatically transmit a JAM packet and create a collision which will cause the far end device to backoff allowing time for the system FIFO to empty itself. The JAM generation feature requires that the RX_EN/JAM pin be programmed for JAM. This can be done by appropriately setting the R/J configuration select bit in the MI serial port Configuration 2 register. 5.13 OSCILLATOR The 80220/80221 requires a 25 Mhz reference frequency for internal signal generation. This 25 Mhz reference frequency can be generated by either connecting an external 25 Mhz crystal between OSCIN and GND or by applying an external 25 Mhz clock to OSCIN. If the crystal oscillator is used, it needs only a crystal, and no other external capacitors or other components are required. The crystal must have the characteristics shown in Table 24. The crystal must be placed as close as possible to OSCIN and GND pins so that parasitics on OSCIN are kept to a minimum. Table 24. Crystal Specifications Parameter Spec Type Parallel Resonant Frequency 25 Mhz +/- 0.01% Equivalent Series 25 ohms max Resistance Load Capacitance 18 pF typ Case Capacitance 7 pF max Power 1mW max Dissipation a.) OUTPUT DRIVER / INPUT ADDRESS CORRESPONDENCE b.) SETTING ADDRESS WITH LEDs 500 500 50 K HIGH LOW c.) SETTING ADDRESS WITHOUT LEDs HIGH LOW FLOAT PLED3 PLED2 PLED1 PLED0 MDINT PLED3 PLED2 PLED1 PLED0 MDINT PLED3 PLED2 PLED1 PLED0 PLED3 PLED2 PLED1 PLED0 MDA3 MDA2 MDA1 MDA0 PLED3 PLED2 PLED1 PLED0 MDINT MDA4 MDINT (OPT) MDINT 50K |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |