49 / 96 page ![]() Preliminary Information 23167B – March 2001 AMD-766 TM Peripheral Bus Controller Data Sheet 49 RTC71: Real-Time Clock Legacy Data Port. IO mapped (fixed); offset: 0071h. Read-write. 7:0 RTCDATA RTCDATA. Real time clock data. This is the data port for accesses to the real-time clock CMOS RAM that is indexed by RTC70. RTC72 and RTC73: Real-Time Clock 256-Byte Address and Data Port. IO mapped (fixed); offsets: 0072h and 0073h. Read-write. These two 8-bit ports are similar to RTC70 and RTC71. However, RTC72, the address register, provides the full eight bits needed to access all 256 bytes of CMOS RAM. RTC73, the data port, provides access to the CMOS data indexed by RTC72. See RTC70 for details about reading RTC72. Real-Time Clock Alarm And Century Registers. RTC indexed address space (indexed by RTC70); offsets: 7Dh, 7Eh, and 7Fh. Attribute: read-write. The day alarm, month alarm, and centenary value are stored in CMOS RAM indexed address space. CMOS RAM offset Function Range for binary mode Range for BCD mode 7Dh Date alarm 01-1Fh 01-31h 7Eh Month alarm 01-0Ch 01-12h 7Fh Century field 13-63h 19-99h Bits[7:6] of the date alarm (offset 7Dh) are reserved; writes to them have no effect and they always read back as zero. To place the RTC into 24-hour alarm mode, an invalid code must be written to bits[5:0] of the date alarm byte (anything other than 01h to 31h for BCD mode or 01h to F1h for hex mode). Refer to the ACPI specification for specifics on the month alarm field (offset 7Eh) and century field (offset 7Fh) functionality. 5.4 Enhanced IDE Controller Configuration Registers (C1Axx) These registers are in PCI configuration space, function 1. See section 5.1.2 for a description of the register naming convention. C1A00: EIDE Controller Vendor And Device ID Configuration space; function 1; offset: 03-00h. C1A00 default: 7411 1022h. Read only. 31:16 15:0 DID VID VID. Vendor ID. DID. EIDE controller device ID. C1A04: EIDE Controller Status And Command Register Configuration space; function 1; offset: 07-04h. Default: 0200 0000h. 31:16 15:0 STATUS[15:0] COMMAND[15:0] COMMAND[0] IO Space, IOEN. Read-write. 1=Enables access to the IO space for the EIDE controller. COMMAND[1] Memory Space. Read only. This bit is fixed in the low state. COMMAND[2] Bus Master Enable, BMEN. Read-write. 1=Enables EIDE bus master capability. COMMAND[15:3]. Read only. These bits are fixed at their default values. STATUS[11:0]. Read only. These bits are fixed at their default values. STATUS[12] Received Target Abort, RTGTABT. Read; set by hardware; write 1 to clear. 1=The IC received a target abort while the EIDE controller was master of the PCI bus. STATUS[13] Received Master Abort, RMASABT. Read; set by hardware; write 1 to clear. 1=An EIDE master cycle was terminated with a master abort. STATUS[15:14]. Read only. These bits are fixed at their default values. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |