15 / 38 page ![]() STG detection is present on VOUT pin with a filter time STG.flt. When short is detected, the FLT pin is asserted low, while MOSFET driving signals HGATE/DGATE depend on the presence of other fault events at the same time. During device power-up, with VOUT externally shorted, blanking time STG_blank is active, STG comparator is masked and has no impact on FLT pin. However, external MOSFET are protected by overcurrent protection features. Table 11. Over current and short to GND parameters Symbol Parameter Test condition Min Typ Max Unit Note OC_HV_th Overcurrent threshold (VSENSE - VOUT), VOUT > STG threshold - 50 55 62.5 mV SENSE, OUT OC_LV_th Overcurrent threshold (VSENSE - VOUT), VOUT < STG threshold - 19 25 32 mV SENSE, OUT OC_HV_fast_th Overcurrent threshold (VSENSE - VOUT), VOUT > STG threshold - 90 100 110 mV SENSE, OUT OC_LV_fast_th Overcurrent threshold (VSENSE- VOUT), VOUT< STG threshold - 38 50 62 mV SENSE, OUT OC_HV_flt Overcurrent filter time STG = 0, guaranteed by scan 80 - 100 μs - OC_LV_flt Overcurrent filter time STG = 1, guaranteed by scan 80 - 100 μs - OC_HV_fast_flt Overcurrent filter time STG = 0, guaranteed by scan and design 1 - 2.2 μs - OC_LV_fast_flt Overcurrent filter time STG = 1, guaranteed by scan and design 1 - 2.2 μs - STG_th OUT short to ground threshold - 2.5 3.2 3.9 V OUT STG_flt Short to ground filter time Guaranteed by scan - - 10 μs - STG_blank Blanking time from driver turning on command Guaranteed by scan 80 - 100 ms - 4.1.5 ENOUT ENOUT is an open-drain output, going in high impedance when the voltage at the OUT pin is above (VB - VFULL_ON), indicating that the external MOSFETs are fully on. ENOUT pin cannot be asserted if WAKE pin voltage is below turn off threshold. Table 12. ENOUT parameters Symbol Parameter Test condition Min Typ Max Unit Note ENOUT_OD_LL ENOUT_OD low level Pull-up current = 1 mA - - 0.4 V ENOUT ENOUT_Leakage ENOUT_OD leakage Apply 5 V to FLT, output buffer off - - 10 μA ENOUT VFULL_ON VB-VOUT difference for releasing ENOUT - 0.5 0.8 1.1 V - FULL_ON_flt Filter time to activate ENOUT Guaranteed by scan - - 100 μs - STPM801 Functional behavior in detail DS13990 - Rev 2 page 15/38 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |