| поискавой системы для электроныых деталей |
|
ADAF1080BCPZ датащи(PDF) 4 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADAF1080BCPZ датащи(HTML) 4 Page - Analog Devices |
|
4 / 36 page ![]() Data Sheet ADAF1080 SPECIFICATIONS analog.com Rev. 0 | 4 of 36 Table 3. Magnetic Range ±4 mT (Continued) Parameter Symbol Test Conditions/Comments Min Typ Max Unit TA = −40°C to +125°C −2.8 +3.3 %SCOEFF1 Linearity Error LERROR ±4 mT range, FSR = 8 mT −0.65 +0.59 %FSR Sensitivity Error due to a Cross Field2 SERROR_BC BCROSS = ±0.5 mT 0.08 %SCOEFF1 Sensitivity Lifetime Error2 0.009 %SCOEFF1 1 Ideal sensitivity, factory trimmed and calculated with the linear best-fit, is measured from the following points: ±4 mT, ±3 mT, ±2 mT, ±1 mT, and ±0.5 mT. 2 Production tested at ±1 mT. Full range guaranteed by design and/or characterization. 3 Ideal coefficient, factory trimmed and calculated with the third-order best-fit, is measured from the following points ±4 mT, ±3 mT, ±2 mT, ±1 mT, and ±0.5 mT. Table 4. Magnetic Range ±8 mT Parameter Symbol Test Conditions/Comments Min Typ Max Unit SENSITIVITY PARAMETERS Ideal Sensitivity1, 2 SCOEFF1 TA = 25°C, VDD = 5 V, G = 80 183 mV/mT TA = 25°C, VDD = 5 V, G = 40 91.5 mV/mT TA = 25°C, VDD = 5 V, G = 20 45.75 mV/mT Nonlinearity Coefficient3 SCOEFF3 TA = 25°C, VDD = 5 V, G = 80 8.08 x 10−8 mV3 /mT Sensitivity Initial Error2 SERROR TA = 25°C −2.19 +2.39 %SCOEFF1 Sensitivity Error over Temperature2 SERROR_TC TA = −20°C to +85°C −0.32 +2.7 %SCOEFF1 TA = −40°C to +125°C −3.56 +3.63 %SCOEFF1 Linearity Error LERROR ±8 mT range, FSR = 16 mT −3.42 +3.28 %FSR Sensitivity Error due to a Cross Field2 SERROR_BC BCROSS = ±0.5 mT 0.06 %SCOEFF1 Sensitivity Lifetime Error2 0.032 %SCOEFF1 1 Ideal sensitivity, factory trimmed and calculated with the linear best-fit, is measured from the following points: ±8 mT, ±7 mT, ±6 mT, ±5 mT, ±4 mT, ±3 mT, ±2 mT, ±1 mT, and ±0.5 mT. 2 Production tested at ±1 mT. Full range guaranteed by design and/or characterization. 3 Ideal coefficient, factory trimmed and calculated with the third-order best-fit, is measured from the following points: ±8 mT, ±7 mT, ±6 mT, ±5 mT, ±4 mT, ±3 mT, ±2 mT, ±1 mT, and ±0.5 mT. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |