| поискавой системы для электроныых деталей |
|
PCF8545ATT датащи(PDF) 13 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PCF8545ATT датащи(HTML) 13 Page - NXP Semiconductors |
|
13 / 103 page ![]() PCA8530 All information provided in this document is subject to legal disclaimers. © NXP Semiconductors N.V. 2014. All rights reserved. Product data sheet Rev. 2 — 25 September 2014 13 of 103 NXP Semiconductors PCA8530 Automotive 102 x 4 Chip-On-Glass LCD segment driver 8.2.7 Command: Status-readout The Status-readout command offers to readout some status bits of the PCA8530. These bits indicate the status of the device at the moment of reading. [1] The flag is set whenever a reset occurs, induced by RST pin, Power-On Reset (POR), or Initialize command. After power-on, the flag is set and should be cleared for reset monitoring. Some bits of the Status-readout command have a certain probability of being changed by an EMC/ESD event. For example, an EMC/ESD event can cause a change of the hard-wired settings of SA1 or SA0. Therefore SR[3:0] can help to detect if an EMC/ESD event has occurred which has caused the change of a bit. In environments where EMC/ESD events may occur, it could be helpful to compare the result of the Status-readout command with the initial bit settings periodically. Table 12. Status-readout - status and temperature read command bit description For this command, bit R/W has to be set logic 1. Bit Symbol Value Description -R/W 1 fixed value - RS[1:0] 00 fixed value Temperature readout if SO = 0 (see Table 11) 7 to 0 TD[7:0] 00000000 to 11111111 temperature readout (see Section 8.10.4.1 on page 40) Device status readout if SO = 1 (see Table 11) 7SR7 display status (see Table 22 on page 21) 0 display is disabled 1 display is enabled 6SR6 charge pump switching status (status of bit CPE, see Table 14 on page 15) 0 charge pump disabled 1 charge pump enabled 5SR5 charge pump charge status 0 charge pump has not reached programmed value 1 charge pump has reached programmed value 4SR4 reset status flag 0 no reset has occurred since the reset status flag was cleared last time 1 reset has occurred since the reset status flag was cleared last time[1] 3 to 0 SR[3:0] EMC detection 01SA1SA0 pre-defined code for EMC detection when I2C interface is used 0101 pre-defined code for EMC detection when SPI interface is used |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |