| поискавой системы для электроныых деталей |
|
TDF8599B датащи(PDF) 16 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
TDF8599B датащи(HTML) 16 Page - NXP Semiconductors |
|
16 / 54 page ![]() NXP Semiconductors TDF8599B I2C-bus controlled dual channel 43 W/2 Ohm, single channel 85 W/1 Ohm class-D power amplifier with load diagnostics TDF8599B All information provided in this document is subject to legal disclaimers. © NXP Semiconductors N.V. 2016. All rights reserved. Product data sheet Rev. 2 — 23 August 2016 16 / 54 In I2C-bus mode, DC offsets generate a voltage shift around the bias voltage. When the voltage shift exceeds threshold values, the offset alarm bit DB1[D2] is set and if bit IB1[D7] is not set, diagnostic information is also given. Any detected offset shuts down both channels when bit IB2[D7] is not set. To restart the TDF8599B in I2C-bus mode, pin EN must be toggled or DCP disabled by connecting pin DCP to pin AGND. In non-I2C-bus mode, when an offset is detected, DCP always gives diagnostic information on pin DIAG and shuts down both channels. Connecting a capacitor between pins DCP and AGND enables DC offset protection. Connecting pin DCP to pin AGND disables DCP in both I2C-bus and non-I2C-bus mode. 8.5.6 Supply voltages UnderVoltage Protection (UVP) is activated when the supply voltage drops below the UVP threshold. UVP triggers the UVP circuit causing the system to first mute and then stop switching. When the supply voltage rises above the threshold level, the system restarts. OverVoltage Protection (OVP) is activated when the supply voltage exceeds the OVP threshold. The OVP (or load dump) circuit is activated and the power stages are shutdown. An overview of all protection circuits and the amplifier states is given in Table 10. 8.5.7 Overview of protection circuits and amplifier states Table 10. Overview of TDF8599B protection circuits and amplifier states Protection circuit name Amplifier state Complete shutdown Channel shutdown Restart[1] TFP N[2] N[2] Y[3] OTP Y N Y[3] OCP N Y Y[4] WP N Y Y DCP Y N N[5] UVP Y N Y[6] OVP Y N Y [1] When fault is removed. [2] Amplifier gain depends on the junction temperature and size of the heat sink. [3] TFP influences restart timing depending on heat sink size. [4] Shorted load causes a restart of the channel every 50 ms. [5] Latched protection is reset by toggling pin EN or by disabling DCP in I2C-bus mode. [6] In I2C-bus mode deep supply voltage drops will cause a Power-On Reset (POR). The restart requires an I2C-bus command. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |