26 / 64 page ![]() Command interface M50FLW080A, M50FLW080B 26/64 4.2 Read Status Register command The Read Status Register command is used to read the Status Register. One Bus Write cycle is required to issue the Read Status Register command. Once the command is issued, subsequent Bus Read operations read the Status Register until another command is issued. See the section on the Status Register for details on the definitions of the Status Register bits. 4.3 Read Electronic Signature command The Read Electronic Signature command is used to read the Manufacturer Code and the Device Code. One Bus Write cycle is required to issue the Read Electronic Signature command. Once the command is issued, the Manufacturer Code and Device Code can be read using conventional Bus Read operations, and the addresses shown in Table 12. The device remains in this mode until another command is issued. That is, subsequent Bus Read operations continue to read the Manufacturer Code, or the Device Code, and not the Memory Array. 4.4 Program command The Program command can be used to program a value to one address in the memory array at a time. The Program command works by changing appropriate bits from ‘1’ to ‘0’. (It cannot change a bit from ‘0’ back to ‘1’. Attempting to do so will not modify the value of the bit. Only the Erase command can set bits back to ‘1’. and does so for all of the bits in the block.) Two Bus Write operations are required to issue the Program command. The second Bus Write cycle latches the address and data, and starts the Program/Erase Controller. Once the command is issued, subsequent Bus Read operations read the value in the Status Register. (See the section on the Status Register for details on the definitions of the Status Register bits.) If the address falls in a protected block, the Program operation will abort, the data in the memory array will not be changed, and the Status Register will indicate the error. During the Program operation, the memory will only accept the Read Status Register command and the Program/Erase Suspend command. All other commands are ignored. See Figure 21, for a suggested flowchart on using the Program command. Typical Program times are given in Table 18. Table 12. Electronic Signature Codes Code Address(1) 1. A22 should be ‘1’, and the ID lines and upper address bits should be set according to the rules illustrated in Table 5, Table 6 and Table 8. Data Manufacturer Code ...00000h 20h Device Code M50FLW080A M50FLW080B ...00001h 80h 81h |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |