12 / 22 page ![]() LTC6955 12 Rev 0 For more information www.analog.com Preliminary Technical Data Advance Product Information Subject to Change Rev PrA OPERATION Table 2. Output Programming with SELx Pins (Note 3) SEL CODE SEL3 SEL2 SEL1 SEL0 # OF ACTIVE OUTPUTS OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 OUT10 TEMP 0 0 0 0 0 0 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF 1 0 0 0 1 3 OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON ON 2 0 0 1 0 4 OFF OFF OFF OFF ON OFF ON OFF ON OFF ON ON 3 0 0 1 1 5 OFF OFF ON OFF ON OFF ON OFF ON OFF ON ON 4 0 1 0 0 6 OFF OFF ON OFF ON OFF ON OFF ON ON ON ON 5 0 1 0 1 7 OFF OFF ON OFF ON OFF ON INV ON INV ON ON 6 0 1 1 0 7 OFF OFF ON OFF ON OFF ON ON ON ON ON ON 7 0 1 1 1 8 OFF OFF ON OFF ON INV ON INV ON INV ON ON 8 1 0 0 0 8 OFF OFF ON OFF ON ON ON ON ON ON ON ON 9 1 0 0 1 9 OFF OFF ON INV ON INV ON INV ON INV ON ON 10 1 0 1 0 9 OFF OFF ON ON ON ON ON ON ON ON ON ON 11 1 0 1 1 10 OFF INV ON INV ON INV ON INV ON INV ON ON 12 1 1 0 0 10 OFF ON ON ON ON ON ON ON ON ON ON ON 13 1 1 0 1 11 ON INV ON INV ON INV ON INV ON INV ON ON 14 1 1 1 0 11 ON ON ON ON ON ON ON ON ON ON ON ON 15 1 1 1 1 0 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON Output Programming The LTC6955’s eleven outputs can be configured by setting the state of the four SELx pins. Three to eleven outputs can be enabled at one time, and odd outputs have the additional ability to be enabled with their output inverted. See Table 2 for full programming details, where OFF means the output is disabled, ON means the output is enabled and not inverted from the input, and INV means the output is enabled and inverted from the input. TEMP Pin The TEMP pin outputs a temperature measurement diode voltage when enabled. For an approximate die tempera- ture, a calibration point is required. Measure the TEMP pin voltage (VTEMPC) with the LTC6955 powered down (SEL3 = SEL2 = SEL1 = SEL0 = 1) at a known tempera- ture (tCAL). Then calculate the operating temperature in a desired application by measuring the TEMP voltage again (VTEMP) and using the following equation: t = 665 • (VTEMPC – VTEMP) + tCAL where t and tCAL are in °C, and VTEMPC and VTEMP are in V. The TEMP diode is enabled in all modes except a full shutdown (SEL3 = SEL2 = SEL1 = SEL0 = 0) as shown in Table 2. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |