| поискавой системы для электроныых деталей |
|
P89LPC907FD датащи(PDF) 32 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
P89LPC907FD датащи(HTML) 32 Page - NXP Semiconductors |
|
32 / 51 page ![]() Philips Semiconductors P89LPC906/907/908 8-bit microcontrollers with two-clock 80C51 core Product data Rev. 05 — 17 December 2004 32 of 51 9397 750 14467 © Koninklijke Philips Electronics N.V. 2004. All rights reserved. 8.11.7 Additional port features After power-up, all pins are in Input-Only mode. Please note that this is different from the LPC76x series of devices. • After power-up all I/O pins, except P1.5, may be configured by software. • Pin P1.5 is input only. Every output on the P89LPC906/907/908 has been designed to sink typical LED drive current. However, there is a maximum total output current for all ports which must not be exceeded. Please refer to Table 13 “DC electrical characteristics” for detailed specifications. All ports pins that can function as an output have slew rate controlled outputs to limit noise generated by quickly switching output signals. The slew rate is factory-set to approximately 10 ns rise and fall times. 8.12 Power monitoring functions The P89LPC906/907/908 devices incorporate power monitoring functions designed to prevent incorrect operation during initial power-up and power loss or reduction during operation. This is accomplished with two hardware functions: Power-on Detect and Brownout detect. 8.12.1 Brownout detection The Brownout detect function determines if the power supply voltage drops below a certain level. The default operation is for a Brownout detection to cause a processor reset, however, it may alternatively be configured to generate an interrupt. Brownout detection may be enabled or disabled in software. If Brownout detection is enabled, the brownout condition occurs when VDD falls below the brownout trip voltage, VBO (see Table 13 “DC electrical characteristics”), and is negated when VDD rises above VBO. If the P89LPC906/907/908 device is to operate with a power supply that can be below 2.7 V, BOE should be left in the unprogrammed state so that the device can operate at 2.4 V, otherwise continuous brownout reset may prevent the device from operating. For correct activation of Brownout detect, the VDD rise and fall times must be observed. Please see Table 13 “DC electrical characteristics” for specifications. 8.12.2 Power-on detection The Power-on Detect has a function similar to the Brownout detect, but is designed to work as power comes up initially, before the power supply voltage reaches a level where Brownout detect can work. The POF flag in the RSTSRC register is set to indicate an initial power-up condition. The POF flag will remain set until cleared by software. 8.13 Power reduction modes The P89LPC906/907/908 supports three different power reduction modes. These modes are Idle mode, Power-down mode, and total Power-down mode. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |