18 / 32 page ![]() Capture-IR State In this controller state, the shift register con- tained in the instruction register loads a fixed value of "01" on the rising edge of J-TCK. This supports fault-isolation of the board-level serial test data path. Data registers selected by the current instruction retain their value during this state. The instruc- tions does not change in this state. When the controller is in this state and a rising edge is applied to J-TCK, the controller enters the Exit1-IR state if J-TMS is held high, or the Shift-IR state if J-TMS is held low. Shift-IR State In this state, the shift register contained in the instruction register is connected between J-TDI and J-TDO and shifts data one stage towards its serial output on each rising edge of J-TCK. The test data register selected by the current in- struction retains its previous value during this state. The instruction does not change in this state. When the controller is in this state and a rising edge is applied to J-TCK, the controller enters the Exit1-IR state if J-TMS is held high, or re- mains in the Shift-IR state if J-TMS is held low. Exit1-IR State This is a temporary state. While in this state, if J-TMS is held high, a rising edge applied to J- TCK causes the controller to enter the Update-IR state, which terminates the scanning process. If J-TMS is held low and a rising edge is applied to J-TCK, the controller enters the Pause-IR state. The test data register selected by the current in- struction retains its previous value during this state. The instruction does not change in this state. Pause-IR State The pause state allows the test controller to tem- porarily halt the shifting of data through the instruction register. The test data register selected by the current in- struction retains its previous value during this state. The instruction does not change in this state. The controller remains in this state as long as J-TMS is low. When J-TMS goes high and a rising edge is applied to J-TCK, the controller moves to the Exit2-IR state. Exit2-IR State This is a temporary state. While in this state, if J-TMS is held high, a rising edge applied to J- TCK causes the controller to enter the Update-IR state, which terminates the scanning process. If J-TMS is held low and a rising edge is applied to J-TCK, the controller enters the Shift-IR state. The test data register selected by the current in- struction retains its previous value during this state. The instruction does not change in this state. Update-IR State The instruction shifted into the instruction regis- ter is latched into the parallel output from the shift-register path on the falling edge of J-TCK. When the new instruction has been latched, it becomes the current instruction. Test data registers selected by the current in- struction retain their previous value. JTAG Application Examples Figures 12 and 13 illustrate examples of updat- ing the instruction and data registers during JTAG operation. 18 DS224PP1 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |