| поискавой системы для электроныых деталей |
|
MP2624GL датащи(PDF) 16 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP2624GL датащи(HTML) 16 Page - Monolithic Power Systems |
|
16 / 45 page ![]() MP2624 – 4.5A SW CHARGER W/ I2C CONTROL, NVDC POWER PATH, USB OTG MP2624 Rev.1.05 www.MonolithicPower.com 16 4/9/2018 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2018 MPS. All Rights Reserved. VSYS regulation is shown in Figure 3. 50mV VSYS_MIN 60mV vBATT vSYS VSYS_MIN + 110mV 100mV VSYS_MIN 60mV vBATT vSYS VSYS_MIN + 160mV Figure 3: VSYS Variation with VBATT The MP2624 monitors continuously the voltage at SYS. Once the system voltage is 100mV over VBATT_FULL + ∆V, it is detected as a VSYS OVP condition. The MP2624 will turn off the DC/DC converter, and then the system will be powered by the battery. Battery Charge Profile The MP2624 provides four main charging phases: trickle charge, pre-charge, constant-current charge, and constant-voltage charge. Phase 1 (Trickle Charge): When the input power is qualified as a good power supply, the MP2624 checks the battery voltage to decide if trickle charge is required. If the battery voltage is lower than VBATT_SHORT (2.1V), a charging current of 128mA is applied on the battery, which helps reset the protection circuit in the battery pack. Phase 2 (Pre-Charge): When the battery voltage exceeds the VBATT_SHORT, the MP2624 starts to pre-charge safely the deeply depleted battery until the battery voltage reaches the “pre-charge to fast-charge threshold” (VBATT_PRE). If VBATT_PRE is not reached before the pre-charge timer expires, the charge cycle ends, and a corresponding timeout fault signal is asserted. The pre-charge current can be programmed via the I2C register REG03 Bit [7:4]. Phase 3 (Constant-Current Charge) When the battery voltage exceeds VBATT_PRE set via the REG04 Bit [1], the MP2624 enters a constant-current charge (fast charge) phase. The fast-charge current can be programmed as high as 4.5A via the REG02 Bit [7:2]. Phase 4 (Constant-Voltage Charge) When the battery voltage rises to the pre- programmable charge full voltage (VBATT_FULL) set via the REG04 Bit [7:2], the charge current begins to taper off. The charge cycle is considered complete when the charge current reaches the battery full termination threshold (IBF) set via the REG03 Bit [3:0], assuming the termination function is enabled by REG05[7] = 1. If IBF is not reached before the safety charge timer expires (see “Safety Timer” section), the charge cycle ends, and the corresponding timeout fault signal is asserted. Figure 4 shows the battery charge profile. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |