| поискавой системы для электроныых деталей |
|
MFC2000 датащи(PDF) 270 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
MFC2000 датащи(HTML) 270 Page - List of Unclassifed Manufacturers |
|
270 / 426 page ![]() MFC2000 Multifunctional Peripheral Controller 2000 Hardware Description 14-4 Conexant 100723A Address Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Default T4 Control (T4Control) $01FF8173 (Not Used) (Not Used) (Not Used) (Not Used) (Not Used) (Not Used) (Not Used) (Not Used) Rst. Value xxh Read Value: 00h Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default T4 Control (T4Control) $01FF8172 Reset T4 Block (w) Terminating Code Error Enable Bi- level Resolution Conversion Decode Output Enable Vertical OR enable (decompress mode only) Reset/Halt Coding or decoding Start coding or decoding Flush CW (completes byte) Rst. Value x0000000b Read Value 00h Bit 15-8: Not used Bit 7: Writing a 1 to this bit causes the T4 logic to be reset, including all internal state machines and FIFOs. This bit is useful when switching between compression and decompression modes. Bit 6: A Terminating Code Error is indicated when a run length = 0 code is expected but not received at the end of a line, and the Terminating Code Error also sets the Line error bit Bit 5: Enable Bi-level Resolution Conversion. Bi-level resolution conversion is only valid in decompression mode. When this bit is set, horizontal resolution conversion will be performed on the decoder output. Both the unconverted line and the converted line will be output to the line buffer. The converted line will be written to the line buffer via DMA channel 8. Bit 4: Decode output enable. Decode Output Enable allows decoded data to be output to the line buffers. This bit should not be set in MH or MR decoding until the first EOL has been found. The decoder output should also be disabled after an error line until the next EOL is found. This bit should always be set for the MMR decoder. Bit 3: Vertical OR enable. The Vertical OR bit is only valid in decompression mode when the bi- level resolution conversion bit in the T4Config register is also set. When the Vertical OR bit is set, the resolution converted decoded output data is ORed with the corresponding byte from the previous line before storing. Bit 2: Reset or halt the coding or decoding. Setting the Reset/Halt bit immediately halts coding or decoding of a line, resets all the T4 Status bits, and clears the active T4Data FIFO. All other bits in this register are ignored if the Reset/Halt bit is set. When coding or decoding is in progress, writing to any bit in this register except Reset/Halt is ignored. Bit 1: Start coding or decoding. The Start bit begins the coding or decoding of the line according to the configuration selected per the T4Config register. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |