| поискавой системы для электроныых деталей |
|
L9659 датащи(PDF) 24 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9659 датащи(HTML) 24 Page - STMicroelectronics |
|
24 / 51 page ![]() Functional description L9659 24/51 Doc ID 022048 Rev 2 During the first write, when the drivers are armed, all diagnostic functions are cleared. The FIRE command must follow the ARM command along with the FEN function active for driver activation. If a command is between the ARM and FIRE command then the sequence must be restarted. An error response will be received for the Fire command if the ARM/FIRE sequence is not followed. The ARM/FIRE commands and FEN function are independent from each other. The L9659 will begin the tDEPLOY timer once a valid ARM/FIRE sequence has been received. If a valid ARM/FIRE command has been sent and the FEN function is inactive then the drivers will not be activated but the tDEPLOY timer will start. If the FEN function becomes active before tDEPLOY has expired then the drivers will become active for the full tDEPLOY time. If the FEN does not become active before tDEPLOY has expired then the sequence would need to be restarted. A diagram illustrating this is shown in Figure 8. Figure 8. Driver activation timing diagram Only the channels selected in the ARM and, directly following, the FIRE command will be able to be activated. By reading the appropriate registers a status of the deployment is provided. If a valid Arm/Fire sequence has been provided the status flag will become active. This flag will remain active for as long as the TDEPLOY timer is counting. Depending on the state of the FEN function the DEPLOY_STATUS flag will be active a minimum of TDEPLOY and a maximum of 2 x TDEPLOY. If driver activation did occur (both a valid Arm/Fire sequence and the appropriate FEN function active within the appropriate time) then the DEPLOY_SUCCESS flag will be active following the completion of the driver activation period. This flag will be active until cleared by software. If a valid Arm/Fire sequence did occur but the FEN function was never activated within the TDEPLOY time then the DEPLOY_SUCCESS flag will remain ‘0’. Once the Deploy Success Flag is set, it will inhibit the subsequent deployment command until a SPI command to clear this deployment success flag is received. Bits D7 through bit D0 are used to clear/keep the deploy success flag. When these bits are set to ‘1,’ the flag |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |