| поискавой системы для электроныых деталей |
|
AD7265ASU датащи(PDF) 14 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7265ASU датащи(HTML) 14 Page - Analog Devices |
|
14 / 16 page ![]() AD7265 Preliminary Technical Data To exit this mode of operation and power up the AD7265 again, a dummy conversion is performed. On the falling edge of CS, the device begins to power up, and continues to power up as long as CS is held low until after the falling edge of the 10th SCLK. The device is fully powered up after approximately 1 µs has elapsed, and valid data results from the next conversion, as shown in Figure 10. If CS is brought high before the second falling edge of SCLK, the AD7265 again goes into partial power- down. This avoids accidental power-up due to glitches on the CS line. Although the device may begin to power up on the falling edge of CS, it powers down again on the rising edge of CS. If the AD7265 is already in partial power-down mode and CS is brought high between the second and 10th falling edges of SCLK, the device enters full power-down mode. FULL POWER-DOWN MODE This mode is intended for use in applications where throughput rates slower than those in the partial power-down mode are required, as power-up from a full power-down takes substan- tially longer than that from partial power-down. This mode is more suited to applications where a series of conversions performed at a relatively high throughput rate are followed by a long period of inactivity and thus power-down. When the AD7265 is in full power-down, all analog circuitry is powered down. Full power-down is entered in a similar way as partial power-down, except the timing sequence shown in Figure 9 must be executed twice. The conversion process must be interrupted in a similar fashion by bringing CS high anywhere after the second falling edge of SCLK and before the 10th falling edge of SCLK. The device enters partial power-down at this point. To reach full power-down, the next conversion cycle must be interrupted in the same way, as shown in Figure TBD. Once CS has been brought high in this window of SCLKs, the part powers down completely. Note that it is not necessary to complete the 14 SCLKs once CS has been brought high to enter a power-down mode. To exit full power-down and power the AD7265 up again, a dummy conversion is performed, as when powering up from partial power-down. On the falling edge of CS, the device begins to power up and continues to power up as long as CS is held low until after the falling edge of the 10th SCLK. The power-up time required must elapse before a conversion can be initiated, as shown in Figure TBD. See the Power-Up Times section for the power-up times associated with the AD7265. 1 A 10 14 1 14 SCLK INVALID DATA VALID DATA DOUTA DOUTB CS TPOWER-UP THE PART BEGINS TO POWER-UP THE PART IS FULLY POWERED UP, SEE POWER-UP TIMES SECTION Figure 10. Exiting Partial Power-Down Mode Rev. PrA | Page 14 of 16 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |