| поискавой системы для электроныых деталей |
|
AD7265ASU датащи(PDF) 13 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7265ASU датащи(HTML) 13 Page - Analog Devices |
|
13 / 16 page ![]() Preliminary Technical Data AD7265 MODES OF OPERATION The mode of operation of the AD7265 is selected by controlling the (logic) state of the CS signal during a conversion. There are three possible modes of operation: normal mode, partial power- down mode, and full power-down mode. The point at which CS is pulled high after the conversion has been initiated determines which power-down mode, if any, the device enters. Similarly, if already in a power-down mode, CS can control whether the device returns to normal operation or remains in power-down. These modes of operation are designed to provide flexible power management options. These options can be chosen to optimize the power dissipation/throughput rate ratio for differing application requirements. accessed on the same DOUT line, as shown in Figure TBD (see the Serial Interface section). The identification bit provided prior to each conversion result identifies which on-board ADC the following result is from. Once 32 SCLK cycles have elapsed, the DOUT line returns to three-state on the 32nd SCLK falling edge. If CS is brought high prior to this, the DOUT line returns to three-state at that point. Thus, CS may idle low after 32 SCLK cycles until it is brought high again sometime prior to the next conversion (effectively idling CS low), if so desired, since the bus still returns to three-state upon completion of the dual result read. Once a data transfer is complete and DOUTA and DOUTB have returned to three-state, another conversion can be initiated after the quiet time, tQUIET, has elapsed by bringing CS low again. NORMAL MODE This mode is intended for fastest throughput rate performance since the user does not have to worry about any power-up times with the AD7265 remaining fully powered all the time. Figure 8 shows the general diagram of the operation of the AD7265 in this mode. PARTIAL POWER-DOWN MODE 110 14 LEADING ZERO, I.D. BIT + CONVERSION RESULT CS SCLK DOUTA DOUTB This mode is intended for use in applications where slower throughput rates are required. Either the ADC is powered down between each conversion, or a series of conversions may be performed at a high throughput rate and the ADC is then powered down for a relatively long duration between these bursts of several conversions. When the AD7265 is in partial power-down, all analog circuitry is powered down except for the on-chip reference and reference buffer. To enter partial power-down, the conversion process must be interrupted by bringing CS high anywhere after the second falling edge of SCLK and before the 10th falling edge of SCLK, as shown in Figure 9. Once CS has been brought high in this window of SCLKs, the part enters partial power-down, the conversion that was initiated by the falling edge of CS is terminated, and DOUTA and DOUTB go back into three-state. If CS is brought high before the second SCLK falling edge, the part remains in normal mode and does not power down. This avoids accidental power-down due to glitches on the CS line. Figure 8. Normal Mode Operation The conversion is initiated on the falling edge of CS, as described in the Serial Interface section. To ensure that the part remains fully powered up at all times, CS must remain low until at least 10 SCLK falling edges have elapsed after the falling edge of CS. If CS is brought high any time after the 10th SCLK falling edge but before the 14th SCLK falling edge, the part remains powered up but the conversion is terminated and DOUTA and DOUTB go back into three-state. Fourteen serial clock cycles are required to complete the conversion and access the conversion result. The DOUT line does not return to three-state after 14 SCLK cycles have elapsed, but instead does so when CS is brought high again. If CS is left low for another 2 SCLK cycles (e.g. if only a 16 SCLK burst is available), two trailing zeros are clocked out after the data. If CS is left low for a further 16 SCLK cycles again, the result from the other ADC on board is also 1 2 10 14 CS SCLK TRI-STATE DOUTA DOUTB Figure 9. Entering Partial Power-Down Mode Rev. PrA | Page 13 of 16 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |